Self-centering second-generation patient-specific functionalized implants for deep orbital reconstruction
- Source :
- Journal of Stomatology, Oral and Maxillofacial Surgery. 122:372-380
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Deep and complete reconstruction of the orbital cavity has been shown to be essential for preventing enophthalmos and hypoglobus in patients with orbital defects or deformities. Additively manufactured patient-specific titanium implants provide unlimited options in design. However, implant malpositioning can still occur, even when intraoperative imaging and navigation are used. In this study, we investigated novel orbital implants containing features facilitating self-centering. Accuracy of implant placement and reconstruction of the orbital dimensions were compared retrospectively between self-centering second-generation patient-specific functionalized orbital implants (study group) and CAD-based individualized implants (control group). Design features of implants in the study group included functionalization with navigation tracks, a preventive design, and flanges - so called stabilizers - towards opposite orbital walls. Implant position was evaluated by fusion of preoperative virtual plans and the post-therapeutic imaging. Aberrances were quantified by 3D heatmap analysis. 31 patients were assigned to the study group and 50 to the control group, respectively. In the study group, most implants were designed with either one (n = 18, 58.06%) or two (n = 10, 32.26%) stabilizers. Twice (6.45%), one stabilizer had to be shortened intraoperatively. Implant fit analysis revealed a significantly more precise (p 0.001) positioning in the study group (n = 22/31) than in the control group (n = 42/50). Self-centering second-generation patient-specific functionalized orbital implants showed significantly more accurate implant positioning, facilitating the transformation of virtual plans into patient's anatomy. The presented design provides an additional instrument for intraoperative quality control besides intraoperative imaging and navigation.
- Subjects :
- Enophthalmos
03 medical and health sciences
0302 clinical medicine
medicine
Humans
In patient
030223 otorhinolaryngology
Orbital Fracture
Orbital Fractures
Intraoperative imaging
Retrospective Studies
Orthodontics
business.industry
030206 dentistry
Plastic Surgery Procedures
Patient specific
Otorhinolaryngology
Orbital reconstruction
Surgery
Orbital cavity
Implant
Oral Surgery
medicine.symptom
business
Orbital Implants
Subjects
Details
- ISSN :
- 24687855
- Volume :
- 122
- Database :
- OpenAIRE
- Journal :
- Journal of Stomatology, Oral and Maxillofacial Surgery
- Accession number :
- edsair.doi.dedup.....ea5eb401c8c0febc9f31688ab54fe58a
- Full Text :
- https://doi.org/10.1016/j.jormas.2020.12.007