Back to Search Start Over

Early post-Humanitarian Device Exemption experience with the Neuroform Atlas stent

Authors :
Mark Bain
Nina Z. Moore
M. Shazam Hussain
Peter A. Rasmussen
Jenny P Tsai
Mohammed H Elgabaly
Thomas J. Masaryk
Gábor Tóth
Lila Sheikhi
Julian Hardman
Source :
Journal of NeuroInterventional Surgery. 11:1141-1144
Publication Year :
2019
Publisher :
BMJ, 2019.

Abstract

IntroductionThe low-profile Neuroform Atlas stent received FDA Humanitarian Device Exemption status (HDE) in January 2018 for stent-assisted coil embolization of wide-necked saccular aneurysms. We review and report our results with the Atlas stent in our institution within the first year after its HDE approval.MethodsOur retrospective chart review identified patients treated with the Atlas stent. We analyzed the patient demographics, aneurysm characteristics, stent parameters and configuration, complications, angiographic, and clinical outcomes at discharge.ResultsFrom January to December 2018, 76 Atlas stents were deployed in 58 patients (average 1.3 stents/patient). Median patient age was 63.5 (IQR 56–71) years. Fifty-six (96.6%) patients had elective embolization of unruptured aneurysms, while two (3.4%) patients underwent embolization of a ruptured aneurysm within 2 weeks of subarachnoid hemorrhage. Forty (69.0%) patients were treated with a single stent, 15 (25.9%) with a Y-stent, and three (5.2%) with X-stent configuration. All stent deployments were technically successful. Most stents (82.9%) were the smallest 3 mm diameter devices. Procedural complications included transient stent-associated thrombosis in three (5.2%) patients and aneurysm rupture in one (1.7%). None had distal embolization, associated cerebral infarction, or permanent neurological deficits. Immediate Raymond–Roy 1 occlusion was achieved in 41 (70.7%) patients. Median hospital length of stay for elective aneurysm embolization was 1 day. Excellent outcomes with median National Institute of Health Stroke Scale score 0 (IQR 0–0) and modified Rankin Score 0 (IQR 0–1) were seen for elective patients at discharge.ConclusionThe Neuroform Atlas stent provided a reliable technical and safety profile for the treatment of intracranial wide-neck aneurysms. Further experience is needed to determine long-term durability and safety of this device.

Details

ISSN :
17598486 and 17598478
Volume :
11
Database :
OpenAIRE
Journal :
Journal of NeuroInterventional Surgery
Accession number :
edsair.doi.dedup.....ea123ad3d3425978c7bd765e0a6c4157
Full Text :
https://doi.org/10.1136/neurintsurg-2019-014874