Back to Search
Start Over
An external fixation method and device to study fracture healing in rats
- Source :
- Acta Orthopaedica Scandinavica. 74:476-482
- Publication Year :
- 2003
- Publisher :
- Medical Journals Sweden AB, 2003.
-
Abstract
- We wished to establish a reproducible model for fracture fixation to be used in fracture healing research and therefore developed an external fixation construct and surgical procedure adapted to Sprague-Dawley rats. We evaluated the mechanical properties of the construct in brass rods and rat bone, in an Instron test machine with axial and transverse loading, and the in vivo performance. We found that the mechanical properties of the construct in brass rods were predictable and could be repeated in rat femora. In all tests, the axial load was about 10 times the transverse for the same degree of deformation. The stiffness among fixators was uniform. 1 mm pins caused about 50% less stiffness than 1.2 mm pins in axial loading of rat bone (p < 0.001) and brass rods (p < 0.001) as well as in transverse loading of brass rods (p < 0.001). Loosening of 1 or 2 screws that lock the pins to the fixator reduced stiffness by about 50% in axial loading of rat bone (p = 0.009) and brass rods (p = 0.05). A change in the distance between the bone surface and the fixator was linearly related to the stiffness in axial loading of rat bone (p < 0.001) and brass rods (p < 0.001) and in transverse loading of brass rods (p < 0.001). If the bone ends touched each other, the axial stiffness of the construct increased almost 10 times (265 N/mm), as compared to a fracture gap size of 2 mm (31 N/mm). In vivo experiments had a complication rate of less than 10% when we used 1.2 mm pins, 6 mm offset and rats weighing 350-450 g. Our method and device for experimental external fixation of rat femora are reliable and the findings are reproducible. These can be used in bone repair and fracture healing research.
- Subjects :
- Male
External Fixators
medicine.medical_treatment
Bone healing
Sensitivity and Specificity
Rats, Sprague-Dawley
Fixation (surgical)
External fixation
Fracture Fixation
Tensile Strength
Fracture fixation
medicine
Animals
Orthopedics and Sports Medicine
Femur
Probability
Fracture Healing
Osteosynthesis
business.industry
Biomechanics
Stiffness
Equipment Design
Anatomy
Biomechanical Phenomena
Rats
Disease Models, Animal
Multivariate Analysis
Surgery
Stress, Mechanical
medicine.symptom
business
Femoral Fractures
Biomedical engineering
Subjects
Details
- ISSN :
- 00016470
- Volume :
- 74
- Database :
- OpenAIRE
- Journal :
- Acta Orthopaedica Scandinavica
- Accession number :
- edsair.doi.dedup.....e912e6c92e7becc97b7763305aff00b9
- Full Text :
- https://doi.org/10.1080/00016470310017820