Back to Search Start Over

Emittance Measurement with Double-Slit Method in CADS Injector-I

Authors :
Meng, Cai
Geng, Huiping
Xue, Zhou
Yan, Fang
Yu, Lingda
Zhao, Yaliang
Source :
Scopus-Elsevier
Publication Year :
2016
Publisher :
JACoW, Geneva, Switzerland, 2016.

Abstract

The C-ADS accelerator is a CW (Continuous-Wave) proton linac with 1.5 GeV in beam energy, 10 mA in beam current, and 15 MW in beam power. CADS Injector-I accelerator is a 10-mA 10-MeV CW proton linac, which uses a 3.2-MeV normal conducting 4-Vane RFQ and superconducting single-spoke cavities for accelerating. The 5MeV test stand of CADS accelerator Injector I is composed of an ion source, a LEBT, a 325MHz RFQ, a MEBT, a cryogenic module (CM1) of seven SC spoke cavities (β=0.12) , seven SC solenoids, seven cold BPMs and a beam dump. Emittance measurement is very important for the understanding of beam behavior and matching to the next accelerating section. Detailed emittance measurement with double-slit method after CM1 are presented in this paper.<br />Proceedings of the 7th Int. Particle Accelerator Conf., IPAC2016, Busan, Korea