Back to Search
Start Over
Utility of fluoroscopy alone for monitoring of intrathoracic bleeding complications during transvenous lead extraction
- Source :
- Journal of Cardiovascular Electrophysiology. 32:1724-1732
- Publication Year :
- 2021
- Publisher :
- Wiley, 2021.
-
Abstract
- BACKGROUND Transvenous lead extraction (TLE) carries a significant risk of major complications, namely bleeding into the pericardial sac or thoracic cavity. While echocardiographic imaging has been recommended for intraprocedural monitoring for those complications, no studies had examined the potential benefits of fluoroscopy alone as an alternative to echocardiography. The aim of this study was to evaluate the utility of fluoroscopy for monitoring intrathoracic bleeding complications during TLE. METHODS This is a single-center retrospective study of consecutive patients who underwent TLE of a pacemaker or ICD lead with fluoroscopy-only monitoring. At the beginning of each TLE procedure, baseline fluoroscopic images were obtained for both lung fields and the cardiac silhouette. Similar images were acquired again when hypotension develops during the procedure. RESULTS Fluoroscopy alone (without echocardiographic imaging) was used in 783 consecutive patients (54% women; average age, 71.5 ± 12.9 years) who underwent TLE. There were 93 patients (11.9%) who experienced significant hypotension. Fluoroscopy showed no obvious cause for hypotension in 63 patients. Right ventricular inversion was implied by fluoroscopy in 27 patients. Fluoroscopy detected new pericardial effusion in two patients and new right pleural effusion in one patient, which prompted halting the extraction procedure and therapeutic intervention. Additionally, routine fluoroscopic images revealed the development of an unsuspected new small left pleural effusion in one patient and a pericardial effusion in another. In-hospital mortality rate was 0%. CONCLUSIONS In selected patients undergoing TLE, fluoroscopy can provide valuable information for identifying or excluding cardiovascular causes during periods of intraprocedural hemodynamic instability.
- Subjects :
- Male
Pacemaker, Artificial
medicine.medical_specialty
Pleural effusion
medicine.medical_treatment
030204 cardiovascular system & hematology
Pericardial effusion
03 medical and health sciences
0302 clinical medicine
Physiology (medical)
medicine
Humans
Fluoroscopy
030212 general & internal medicine
Device Removal
Aged
Retrospective Studies
Aged, 80 and over
Lung
medicine.diagnostic_test
business.industry
Thoracic cavity
Retrospective cohort study
Middle Aged
medicine.disease
Implantable cardioverter-defibrillator
Defibrillators, Implantable
Treatment Outcome
medicine.anatomical_structure
Ventricular inversion
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 15408167 and 10453873
- Volume :
- 32
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiovascular Electrophysiology
- Accession number :
- edsair.doi.dedup.....e7d4c565e0f93ed62c054c35583c1fd4
- Full Text :
- https://doi.org/10.1111/jce.14995