Back to Search
Start Over
Hypothermic machine perfusion can safely prolong cold ischemia time in deceased donor kidney transplantation. A retrospective analysis on postoperative morbidity and graft function
- Source :
- Artificial organsREFERENCES. 45(5)
- Publication Year :
- 2020
-
Abstract
- In deceased donor kidney transplantation (KT), a prolonged cold ischemia time (CIT) is a negative prognostic factor for KT outcome, and the efficacy of hypothermic machine perfusion (HMP) in prolonging CIT without any additional hazard is highly debated. We conducted a retrospective study on a cohort of 154 single graft deceased donor KTs, in which a delayed HMP, after a preliminary period of static cold storage (SCS), was used to prolong CIT for logistic reasons. Primary outcomes were postoperative complications as well as 1 year graft survival and function. 73 cases (47.4%) were managed with HMP and planned KT, while 81 (52.6%) with SCS and urgent KT. The median CIT in HMP group and SCS group was 29 hour:57 minutes [27-31 hour:45 minutes] and 11 hour:25 minutes [9-14 hour:30 minutes], respectively (P < .001). The period of SCS in the HMP group was significantly shorter than in the SCS group (10 vs. 11 hour:25 minutes, P = .02) as well as the prevalence of expanded criteria donors was significantly higher (43.8% vs. 18.5%, P < .01). After propensity score matching for these two baseline characteristics, the HMP and SCS groups showed comparable outcomes in terms of delayed graft function, vascular, and urologic complications, infections, and episodes of graft rejection. At 1 year follow-up, serum creatinine levels were comparable between the groups. Therefore, the use of HMP to prolong the CIT and convert KT into a planned procedure seemed to have an adequate safety profile, with outcomes comparable to KT managed as an urgent procedure and a CIT nearly three time shorter.
- Subjects :
- Graft Rejection
Male
Time Factors
0206 medical engineering
Biomedical Engineering
Medicine (miscellaneous)
Cold storage
Delayed Graft Function
Bioengineering
02 engineering and technology
030204 cardiovascular system & hematology
Kidney
Cold Ischemia Time
Biomaterials
03 medical and health sciences
chemistry.chemical_compound
hypothermic machine perfusion
0302 clinical medicine
Postoperative Complications
medicine
Humans
Kidney transplantation
Aged
Retrospective Studies
Creatinine
Machine perfusion
business.industry
Cold Ischemia
Graft Survival
Retrospective cohort study
General Medicine
Organ Preservation
Middle Aged
medicine.disease
Allografts
020601 biomedical engineering
Kidney Transplantation
cold ischemia time
Transplantation
Perfusion
Treatment Outcome
chemistry
kidney transplant morbidity
Anesthesia
Propensity score matching
delayed graft function
kidney transplantation
Female
business
Subjects
Details
- ISSN :
- 15251594
- Volume :
- 45
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Artificial organsREFERENCES
- Accession number :
- edsair.doi.dedup.....e6f3e4268c02c531f2a766534f56429c