Back to Search
Start Over
Correlations among ocular surface temperature difference value, the tear meniscus height, Schirmer's test and fluorescein tear film break up time
- Source :
- British Journal of Ophthalmology. 99:482-487
- Publication Year :
- 2014
- Publisher :
- BMJ, 2014.
-
Abstract
- Purpose To report the use of a thermographer for measuring ocular surface temperature, and to evaluate the correlation among the obtained temperature difference values (TDVs) and dry eye parameters (tear meniscus height (TMH); Schirmer9s test results; fluorescent tear breakup time (FTBUT)). Methods Forty-three participants (age 40.2±14.7 years; range 21–67 years) from Far Eastern Memorial Hospital, Taiwan were recruited for the study. The surface temperature was measured at the centre of the ocular surface for 4 s after blinking. TDV was defined as the change in corneal surface temperature relative to that of the preceding eye opening, where TDV01, TDV02, TDV03, and TDV04 represent the values obtained 1, 2, 3, and 4 s after blinking, respectively. Anterior segment optical coherence tomography (AS-OCT) was employed to measure the lower TMH. Schirmer9s test with topical anaesthetic was conducted to measure the basal tear secretion. The FTBUT was recorded using a digital camera. Results TDV measurement exhibited high reliability (intraclass correlation coefficient=0.91). TDV03 exhibited the highest significance and strongest positive correlation with the TMH (r=0.52, p=0.0003) and Schirmer9s test value (r=0.39, p=0.008), whereas the TDV03–FTBUT correlation was non-significant. Age correlated negatively and significantly with the TDV (r= −0.35, p=0.021), TMH (r= −0.33, p=0.031), and Schirmer9s test value (r= −0.31, p=0.044). TDV03 remained significantly correlated with the TMH and Schirmer9s test value after adjustment for age. Conclusions The thermographer was effective in capturing temperature changes in the ocular surface. The temperature difference 3 s after blinking appears to be correlated with lower TMH and Schirmer test values.
- Subjects :
- Adult
Male
medicine.medical_specialty
Intraclass correlation
Body Temperature
Cornea
Young Adult
Cellular and Molecular Neuroscience
chemistry.chemical_compound
Ophthalmology
Tear meniscus height
medicine
Humans
Schirmer's test
Tear secretion
Temperature difference
Fluorescein
Aged
Fluorescent Dyes
Blinking
medicine.diagnostic_test
business.industry
Reproducibility of Results
Middle Aged
eye diseases
Sensory Systems
Surgery
chemistry
Thermography
Tears
Dry Eye Syndromes
Female
sense organs
business
Ocular surface
Tomography, Optical Coherence
Subjects
Details
- ISSN :
- 14682079 and 00071161
- Volume :
- 99
- Database :
- OpenAIRE
- Journal :
- British Journal of Ophthalmology
- Accession number :
- edsair.doi.dedup.....e6d200dbe9c6d63cd2fa4365c70f4e66
- Full Text :
- https://doi.org/10.1136/bjophthalmol-2014-305183