Back to Search Start Over

All-inside technique versus in situ transtendon repair for Ellman Ⅲ partial articular supraspinatus tendon avulsion

Authors :
Tao Yuan
Shaoqiang Yang
Hong Qian
Chengteng Lai
Hui Jiang
Jia Meng
Jianning Zhao
Nirong Bao
Source :
Journal of shoulder and elbow surgery. 32(1)
Publication Year :
2022

Abstract

The current surgical techniques for repairing Ellman Ⅲ partial articular supraspinatus tendon avulsion (PASTA) is mainly tear completion followed by repair and in situ transtendon repair, and both techniques have been proven to have good clinical effects. In situ transtendon repair is more widely used because of its high performance in preserving the integrity of the bursal side supraspinatus tendon. However, there is still some scope for improvement. Our purpose was to compare the clinical outcomes of the all-inside repair technique and in situ transtendon repair for Ellman III PASTA.A retrospective comparative study was conducted on 56 patients who suffered from Ellman Ⅲ PASTA and underwent rotator cuff repair; 28 patients were treated with the all-inside technique (group A), and 28 patients were treated with the transtendinous technique (group B). All patients were followed up for at least 2 years. The visual analog scale (VAS), Constant, and American Shoulder and Elbow Surgeons (ASES) scores were used to evaluate the patient's shoulder joint function before surgery, 1 month and 3 months after surgery, and at the last time of follow-up.Group A showed superiority in pain and functional improvement 1 month after the operation: the VAS score, 2.8 ± 0.3 in group A vs. 4.7 ± 0.4 in group B (P = .042); Constant score, 73 ± 5 in group A vs. 60 ± 6 in group B (P = .038); and ASES score, 75 ± 5 in group A vs. 58 ± 7 in group B (P = .043), whereas there was no statistical difference in group B. However, 3 months after surgery and at the last follow-up, the VAS, Constant, and ASES scores in both groups were significantly improved (P .01), and there was no significant statistical difference between the groups (P.05). Magnetic resonance imaging showed that the repaired rotator cuff tendon-bone healed well; at the last follow-up, all patients were in good function, the pain was completely relieved, and no revision was performed in both groups.Arthroscopic repair of Ellman Ⅲ PASTA provided satisfactory functional improvements and pain relief regardless of the all-inside and in situ transtendon repair techniques. However, the all-inside repair technique is more beneficial due to its dual function in preserving the intact bursa and avoidance of uneven tension of the articular side, which is advantageous to early postoperative rehabilitation.

Details

ISSN :
15326500
Volume :
32
Issue :
1
Database :
OpenAIRE
Journal :
Journal of shoulder and elbow surgery
Accession number :
edsair.doi.dedup.....e6833dfdbb46aa6020dba4483b8fd036