Evaluation of the accuracy of deformable image registration on MRI with a physical phantom
- Source :
- Journal of Applied Clinical Medical Physics
- Publication Year :
- 2019
-
Abstract
- Background and purpose Magnetic resonance imaging (MRI) has gained popularity in radiation therapy simulation because it provides superior soft tissue contrast, which facilitates more accurate target delineation compared with computed tomography (CT) and does not expose the patient to ionizing radiation. However, image registration errors in commercial software have not been widely reported. Here we evaluated the accuracy of deformable image registration (DIR) by using a physical phantom for MRI. Methods and materials We used the “Wuphantom” for end‐to‐end testing of DIR accuracy for MRI. This acrylic phantom is filled with water and includes several fillable inserts to simulate various tissue shapes and properties. Deformations and changes in anatomic locations are simulated by changing the rotations of the phantom and inserts. We used Varian Velocity DIR software (v4.0) and CT (head and neck protocol) and MR (T1‐ and T2‐weighted head protocol) images to test DIR accuracy between image modalities (MRI vs CT) and within the same image modality (MRI vs MRI) in 11 rotation deformation scenarios. Large inserts filled with Mobil DTE oil were used to simulate fatty tissue, and small inserts filled with agarose gel were used to simulate tissues slightly denser than water (e.g., prostate). Contours of all inserts were generated before DIR to provide a baseline for contour size and shape. DIR was done with the MR Correctable Deformable DIR method, and all deformed contours were compared with the original contours. The Dice similarity coefficient (DSC) and mean distance to agreement (MDA) were used to quantitatively validate DIR accuracy. We also used large and small regions of interest (ROIs) during between‐modality DIR tests to simulate validation of DIR accuracy for organs at risk (OARs) and propagation of individual clinical target volume (CTV) contours. Results No significant differences in DIR accuracy were found for T1:T1 and T2:T2 comparisons (P > 0.05). DIR was less accurate for between‐modality comparisons than for same‐modality comparisons, and was less accurate for T1 vs CT than for T2 vs CT (P
- Subjects :
- Male
87.55.dk
Computer science
87.55.Qr
Planning target volume
Image registration
Computed tomography
Imaging phantom
030218 nuclear medicine & medical imaging
87.57.nj
03 medical and health sciences
deformable phantom
0302 clinical medicine
Medical Imaging
medicine
Image Processing, Computer-Assisted
Humans
Radiology, Nuclear Medicine and imaging
Head and neck
deformable image registration
Instrumentation
Radiation
MR multimodality image registration
medicine.diagnostic_test
Phantoms, Imaging
Radiotherapy Planning, Computer-Assisted
Prostatic Neoplasms
Magnetic resonance imaging
Radiotherapy Dosage
89.20.-a
Magnetic Resonance Imaging
Distance to agreement
Soft tissue contrast
Head and Neck Neoplasms
030220 oncology & carcinogenesis
Algorithms
Biomedical engineering
Subjects
Details
- ISSN :
- 15269914
- Volume :
- 21
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Journal of applied clinical medical physics
- Accession number :
- edsair.doi.dedup.....e6163f6bc35804eea6c76b7c28338793