Abstract
- The aim of this study was to investigate the accuracy and efficacy of two commonly used commercial immobilization systems for stereotactic body radiation therapy (SBRT) in lung cancer. This retrospective study assessed the efficacy and setup accuracy of two immobilization systems: the Elekta Body Frame (EBF) and the Civco Body Pro‐Lok (CBP) in 80 patients evenly divided for each system. A cone beam CT (CBCT) was used before each treatment fraction for setup correction in both devices. Analyzed shifts were applied for setup correction and CBCT was repeated. If a large shift (>5 mm) occurred in any direction, an additional CBCT was employed for verification after localization. The efficacy of patient setup was analyzed for 105 sessions (48 with the EBF, 57 with the CBP). Result indicates that the CBCT was repeated at the 1st treatment session in 22.5% and 47.5% of the EBF and CBP cases, respectively. The systematic errors {left–right (LR), anterior–posterior (AP), cranio‐caudal (CC), and 3D vector shift: (LR 2 + AP 2 + CC 2)1/2 (mm)}, were {0.5 ± 3.7, 2.3 ± 2.5, 0.7 ± 3.5, 7.1 ± 3.1} mm and {0.4 ± 3.6, 0.7 ± 4.0, 0.0 ± 5.5, 9.2 ± 4.2} mm, and the random setup errors were {5.1, 3.0, 3.5, 3.9} mm and {4.6, 4.8, 5.4, 5.3} mm for the EBF and the CBP, respectively. The 3D vector shift was significantly larger for the CBP (P < 0.01). The setup time was slightly longer for the EBF (EBF: 15.1 min, CBP: 13.7 min), but the difference was not statistically significant. It is concluded that adequate accuracy in SBRT can be achieved with either system if image guidance is used. However, patient comfort could dictate the use of CBP system with slightly reduced accuracy.
- Subjects :
- Systematic error
Body frame
Lung Neoplasms
Stereotactic body radiation therapy
Radiotherapy Setup Errors
setup accuracy
Radiosurgery
Patient Positioning
030218 nuclear medicine & medical imaging
lung
03 medical and health sciences
Immobilization
0302 clinical medicine
Medicine
Radiation Oncology Physics
Humans
Radiology, Nuclear Medicine and imaging
Image guidance
Instrumentation
Cone beam ct
Patient comfort
Retrospective Studies
Radiation
SBRT
business.industry
Radiotherapy Planning, Computer-Assisted
87.55.km
setup efficacy
Cone-Beam Computed Tomography
immobilization device
030220 oncology & carcinogenesis
business
Nuclear medicine
Subjects
Details
- Language :
- English
- ISSN :
- 15269914
- Volume :
- 18
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Clinical Medical Physics
- Accession number :