Back to Search
Start Over
Intercondylar eminence fracture treated by resorbable magnesium screws osteosynthesis: A case series
- Source :
- Injury. 49
- Publication Year :
- 2018
-
Abstract
- Introduction Tibial spine avulsion fractures are mostly a paediatric injury which appropriate treatment is currently debated in literature. The choice between conservative and surgical treatment is based on the radiographic classification of Meyers-McKeever. The most diffused surgical techniques involve either internal fixation devices (screws) or bone tunnels fixation with resorbable sutures. Today, a third option is represented by resorbable magnesium screws which could combine the best features of the two classical systems. Objective of this study is to investigate the efficacy of these new devices in the surgical treatment of tibial spine avulsions. Materials and methods Since 2014 we have seen seven patients with tibial eminence fracture. Patients underwent clinical and radiological examination (MRI, CT scan) before surgery. Only 3 patients that presented with a grade III or IV lesion were treated surgically with internal fixation with magnesium resorbable screws. In post-operative follow-up, functional recovery was evaluated at 1, 2, 4, 6 and 12 months, clinically and by X-ray. Lysholm and IKDC scores were submitted at 1, 2, 6 and 12 months. MRI was repeated at 6 and 12 months. Results All three surgical patients showed progressive clinical and functional improvement during the follow-up period. The first case showed a quicker overall recovery rate, which might be due to the lower grade of the lesion. Radiographs and MRI evaluation showed regular healing of the injury. The devices appeared completely resorbed at the 6 months follow-up and replaced by newly formed bone at the 12 months follow-up. Conclusions The treatment of tibial spine avulsion fractures with arthroscopic reduction and internal fixation (ARIF) technique by magnesium resorbable screws seems to result in an excellent functional recovery without complications related to fixation devices, which were completely resorbed after 6 months and replaced by newly formed bone after 12 months. This new method could be considered as an alternative option to classic techniques by non resorbable fixation devices or bone tunnel fixation. Further studies are needed in order to evaluate the efficacy of these new devices in a wider group of patients.
- Subjects :
- musculoskeletal diseases
Male
medicine.medical_specialty
Adolescent
Knee Joint
Radiography
medicine.medical_treatment
Bone Screws
02 engineering and technology
Avulsion
03 medical and health sciences
Fixation (surgical)
Fracture Fixation, Internal
Young Adult
0302 clinical medicine
Absorbable Implants
medicine
Internal fixation
Humans
Magnesium
Tibia
Range of Motion, Articular
General Environmental Science
030222 orthopedics
Osteosynthesis
business.industry
Avulsion fracture
musculoskeletal system
021001 nanoscience & nanotechnology
medicine.disease
Surgery
Tibial Fractures
Fractures, Avulsion
Treatment Outcome
Case-Control Studies
Athletic Injuries
General Earth and Planetary Sciences
Female
0210 nano-technology
business
Subjects
Details
- ISSN :
- 18790267
- Volume :
- 49
- Database :
- OpenAIRE
- Journal :
- Injury
- Accession number :
- edsair.doi.dedup.....e5ad7f6a6c4465aa45e4117140685fd0