Back to Search
Start Over
Utility of Water Siphon Maneuver for Eliciting Gastroesophageal Reflux During Barium Esophagography: Correlation With Histologic Findings
- Source :
- American Journal of Roentgenology. 211:335-339
- Publication Year :
- 2018
- Publisher :
- American Roentgen Ray Society, 2018.
-
Abstract
- The objective of this study is to evaluate whether the water siphon maneuver improves detection of gastroesophageal (GE) reflux during barium esophagography compared with observation for spontaneous reflux only. Histopathologic analysis is the reference standard.This retrospective study assessed 87 outpatients who underwent both barium esophagography and upper endoscopy-guided biopsy within a 30-day interval. The water siphon maneuver was routinely performed when spontaneous GE reflux was not observed during the fluoroscopic study. Radiology reports were reviewed for mentions of the presence of reflux and the circumstances in which it was observed (as a spontaneous occurrence or as a result of the water siphon maneuver). Pathology reports from subsequent endoscopic biopsies were reviewed to identify histologic changes of reflux disease. The sensitivity, specificity, and accuracy of esophagography, observation for spontaneous reflux, and the water siphon maneuver were calculated and then compared using a McNemar test.Of the 87 patients, 57 (65.5%) had GE reflux diagnosed on the basis of histologic changes noted on endoscopy, and 30 (34.5%) did not. A total of 57 patients (65.5%) showed reflux during esophagography, 41 (71.9%) of whom had reflux diagnosed by the water siphon maneuver, and 16 (28.1%) had reflux diagnosed on the basis of observation of spontaneous reflux. Forty-four patients had reflux diagnosed on the basis of both a barium study and histologic findings; 13 patients had reflux noted on esophagography but had negative histologic findings. The overall sensitivity, specificity, and accuracy of esophagography for reflux were 77.2%, 56.7%, and 70.1%, respectively. Spontaneous reflux alone had a sensitivity, specificity, and accuracy of 21.1%, 86.7%, and 43.7%, respectively. The water siphon maneuver showed a sensitivity of 71.1%, a specificity of 65.4%, and accuracy of 69.0%. The differences in the sensitivity, specificity, and accuracy of the water siphon maneuver versus observation of spontaneous reflux were statistically significant (p ≤ 0.004).A properly performed and interpreted water siphon maneuver significantly increases the sensitivity and accuracy for GE reflux during esophagography, compared with observation for spontaneous reflux alone. The water siphon maneuver is a simple addition to barium esophagography that improves sensitivity and accuracy for the diagnosis of GE reflux compared with observation alone.
- Subjects :
- Adult
Image-Guided Biopsy
Male
medicine.medical_specialty
genetic structures
Contrast Media
chemistry.chemical_element
Sensitivity and Specificity
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Retrospective Studies
Siphon (insect anatomy)
Esophagram
business.industry
digestive, oral, and skin physiology
Reflux
Water
Barium
General Medicine
Middle Aged
digestive system diseases
chemistry
030220 oncology & carcinogenesis
Esophagography
Gastroesophageal Reflux
Female
030211 gastroenterology & hepatology
Esophagoscopy
Radiology
Barium Sulfate
business
Subjects
Details
- ISSN :
- 15463141 and 0361803X
- Volume :
- 211
- Database :
- OpenAIRE
- Journal :
- American Journal of Roentgenology
- Accession number :
- edsair.doi.dedup.....e5a82e6919a999dd08d4ca924b2c26f8
- Full Text :
- https://doi.org/10.2214/ajr.17.19063