Back to Search
Start Over
Reliability of a novel dynamic test of postural stability in high-level soccer players
- Source :
- Heliyon, Beelen, P E, Okhuijsen, R, Prins, M R, Huurnink, A, Hordijk, T, Kruiswijk, C, Goedhart, E A, van der Wurff, P, Nolte, P A, van Dieën, J H & Kingma, I 2021, ' Reliability of a novel dynamic test of postural stability in high-level soccer players ', Heliyon, vol. 7, no. 4, e06647, pp. 1-8 . https://doi.org/10.1016/j.heliyon.2021.e06647, Heliyon, Vol 7, Iss 4, Pp e06647-(2021), Heliyon, 7(4):e06647, 1-8. Elsevier BV
- Publication Year :
- 2021
- Publisher :
- Elsevier, 2021.
-
Abstract
- Postural stability of athletes is commonly tested with single-leg stance (SLS) tests. However, for this population, these tests are insufficiently challenging to achieve high sensitivity. Therefore, a new dynamic SLS test based on standardized translational surface perturbations was developed. This study aimed to assess reliability, sensitivity to learning effects, and internal and concurrent validity of this novel test. Healthy soccer players (21 females, 21 males) performed 2 test sessions. Each session consisted of 2 trials. For one trial, the participant performed a 30-seconds, unperturbed SLS on each leg, followed by 12 platform perturbations per leg. Intraclass Correlation Coefficients (ICC) and correlations between outcomes were calculated for the Center of Pressure speed (CoPs) and Time To Stabilization (TTS). ANOVA was used to assess learning effects. CoPs and TTS showed a fair reliability between sessions (ICC = 0.73–0.76). All variables showed improvement over time within and between sessions (all p < 0.01) and were moderately correlated with CoPs during unperturbed SLS (r = 0.39–0.56). Single-leg dynamic postural stability testing through standardized horizontal platform perturbations yielded sufficiently reliable CoPs and TTS outcome measures in soccer players. The moderate correlations with unperturbed SLS support concurrent validity, but also indicates that the new test captures aspects of postural stability that differ from the conventional, unperturbed SLS test.<br />Postural stability; Perturbation; Time to stabilization; Center of pressure speed.
- Subjects :
- 0301 basic medicine
medicine.medical_specialty
Science (General)
Intraclass correlation
Population
Concurrent validity
Postural stability
03 medical and health sciences
Q1-390
0302 clinical medicine
Physical medicine and rehabilitation
medicine
education
Reliability (statistics)
Mathematics
H1-99
education.field_of_study
Multidisciplinary
Time To Stabilization
Test (assessment)
Perturbation
Social sciences (General)
030104 developmental biology
Center of Pressure speed
Analysis of variance
030217 neurology & neurosurgery
Dynamic testing
Center of pressure (fluid mechanics)
Research Article
Subjects
Details
- Language :
- English
- ISSN :
- 24058440
- Volume :
- 7
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Heliyon
- Accession number :
- edsair.doi.dedup.....e283468217bc5f74b857ceaced147bec
- Full Text :
- https://doi.org/10.1016/j.heliyon.2021.e06647