Back to Search Start Over

Fabrication and characterization of large numerical aperture, high-resolution optical fiber bundles based on high-contrast pairs of soft glasses for fluorescence imaging

Authors :
Dariusz Pysz
Müjdat Zeybel
Musa Aydin
Buket Yiğit
Berna Morova
B. Doğan
Nima Bavili
Rafal Kasztelanic
Ryszard Buczynski
Alper Kiraz
Onur Yaman
Morova, Berna
Bavili, Nima
Yaman, Onur
Yiğit, Buket
Zeybel, Müjdat (ORCID 0000-0002-1542-117X & YÖK ID 214694)
Kiraz, Alper (ORCID 0000-0001-7977-1286 & YÖK ID 22542)
Aydın, Musa
Doğan, Buket
Kasztelanic, Rafal
Pysz, Dariusz
Buczynski, Ryszard
College of Sciences
School of Medicine
College of Engineering
Department of Physics
Department of Gastroenterology and Hepatology
Department of Electrical and Electronics Engineering
Source :
Optics Express
Publication Year :
2019
Publisher :
The Optical Society, 2019.

Abstract

Fabrication and characterization of flexible optical fiber bundles (FBs) with in-house synthesized high-index and low-index thermally matched glasses are presented. The FBs composed of around 15000 single-core fibers with pixel sizes between 1.1 and 10 mu m are fabricated using the stack-and-draw technique from sets of thermally matched zirconium-silicate ZR3, borosilicate SK222, sodium-silicate K209, and F2 glasses. With high refractive index contrast pair of glasses ZR3/SK222 and K209/F2, FBs with numerical apertures (NAs) of 0.53 and 0.59 are obtained, respectively. Among the studied glass materials, ZR3, SK222, and K209 are in-house synthesized, while F2 is commercially acquired. Seven different FBs with varying pixel sizes and bundle diameters are characterized. Brightfield imaging of a micro-ruler and a Convallaria majalis sample and fluorescence imaging of a dye-stained paper tissue and a cirrhotic mice liver tissue are demonstrated using these FBs. demonstrating their good potential for microendoscopic imaging. Brightfield and fluorescence imaging performance of the studied FBs are compared. For both sets of glass compositions, good imaging performance is observed for FBs, with core diameter and core-to-core distance values larger than 1.6 mu m and 2.3 mu m, respectively. FBs fabricated with K209/F2 glass pairs revealed better performance in fluorescence imaging due to their higher NA of 0.59.<br />Smart Growth Operational Programme; EU-H2020-ICT-2014 grant MIREGAS: Programmable multi-wavelength Mid-IR source for gas sensing; Foundation for Polish Science Team Programme; European Regional Development Fund; European Union (European Union); H2020

Details

ISSN :
10944087
Volume :
27
Database :
OpenAIRE
Journal :
Optics Express
Accession number :
edsair.doi.dedup.....e274bdf2da5cd9a473d16039b3b004a7