Back to Search Start Over

Is bearing resistance negligible during wheelchair locomotion? Design and validation of a testing device

Authors :
Bascou, Joseph
Sauret, Christophe
Lavaste, Francois
Hélène, Pillet
Arts et Métiers ParisTech
HESAM Université (HESAM)
Laboratoire de biomécanique (LBM)
Université Paris 13 (UP13)-Université Sorbonne Paris Cité (USPC)-Université Paris-Est Créteil Val-de-Marne - Paris 12 (UPEC UP12)-Centre National de la Recherche Scientifique (CNRS)
Institut de Biomecanique Humaine Georges Charpak
Université Paris 13 (UP13)-Arts et Métiers ParisTech
Administrateur Ensam, Compte De Service
HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)
Source :
Acta of Bioengineering and Biomechanics, Acta of Bioengineering and Biomechanics, Wroclaw University of Technology, 2017, 19 (3), pp.165-176
Publication Year :
2017
Publisher :
HAL CCSD, 2017.

Abstract

International audience; Purpose: Among the different resistances occurring during wheelchair locomotion and that limit the user autonomy, bearing resistance is generally neglected, based on a few studies carried out in static conditions and by manufacturer’s assertion. Therefore, no special attention is generally paid to the mounting and the maintenance of manual wheelchair bearings. However, the effect of inadequate mounting or maintenance on wheelchair bearing resistance has still to be clarified. This study aimed at filling this gap by developing and validating a specific device allowing the measurement of wheelchair bearing friction, characterized by low speed velocities, with an accuracy lower than 0.003 Nm.Methods: The bearing resistance measured by the device was compared to free deceleration measurement, intra and inter operator reproducibility were assessed. A factorial experiment allowed the effects of various functioning parameters (axial and radial loads, velocity) to be classified.Results: The device allowed significant differences in the bearing resistance of static and rotating conditions to be measured, even if a relatively high proportionality was found between both conditions. The factorial experiment allowed the expected impact of the radial load on bearing resistance as well as the predominant effect of the axial load to be demonstrated.Conclusions: As a consequence, it appeared that the control of the axial load is compulsory for measurement purposes or during wheel mounting, to avoid significant increase of global resistance during wheelchair locomotion. The findings of this study could help enhancing the models which assess manual wheelchair mechanical power from its settings and use conditions.

Details

Language :
English
ISSN :
1509409X
Database :
OpenAIRE
Journal :
Acta of Bioengineering and Biomechanics, Acta of Bioengineering and Biomechanics, Wroclaw University of Technology, 2017, 19 (3), pp.165-176
Accession number :
edsair.doi.dedup.....e24a9e2da8e45592ebc3784d69fcab52