Back to Search
Start Over
Apical Myocardial Stunning in a Large Size Porcine Model Assessed by Strain and Strain Rate Echocardiography
- Source :
- Høyer, C, Aagaard, S R, Pedersen, T F, Andersen, N T, Hasenkam, J M & Sloth, E 2007, ' Apical Myocardial Stunning in a Large Size Porcine Model Assessed by Strain and Strain Rate Echocardiography ', Echocardiography: A Journal of Cardiovascular Ultrasound and Allied Techniques, vol. 24, no. 9, pp. 923-932 . https://doi.org/10.1111/j.1540-8175.2007.00498.x
- Publication Year :
- 2007
- Publisher :
- Wiley, 2007.
-
Abstract
- BACKGROUND Warm ischemia and subsequent reperfusion of the heart can induce a temporary dysfunction known as myocardial stunning. The aim of this study was to investigate the ability of tissue Doppler imaging (TDI) to quantify longitudinal myocardial stunning close to the apex, and perform a comparison with sonomicrometry using a well-established large size porcine model. METHODS In anesthetized pigs, postischemic myocardial stunning was induced by occluding LAD for 15 min followed by 90 min reperfusion (n = 7). Long-axis strain and strain rate was quantified by both TDI and sonomicrometry. RESULTS During reperfusion, peak systolic strain measured by TDI decreased from -11.2% (+/-3.0) at baseline to -4.9% (+/-3.6), -3.4% (+/-2.9), and -4.3% (+/-5.0) at 30, 60, and 90 min, respectively (all P < 0.007). Postsystolic strain increased from -1.3% (+/-1.6) at baseline to -6.4% (+/-4.4), -4.8% (+/-4.0), and -5.2% (+/-2.7) by TDI in the reperfusion phase (all P < 0.048 except at 60 min of reperfusion (P = 0.081)). Postsystolic index increased from 0.10 (+/-0.13) at baseline to 0.56 (+/-0.24), 0.54 (+/-0.30), and 0.64 (+/-0.37) subsequently (all P < 0.012). [Correction added after online publication 30-May-2007: In the preceding sentence, the phrase 'Postsystolic index decreased from 0.10 (+/-0.13)' was changed to 'Postsystolic index increased from 0.10 (+/-0.13).'] Difference-mean and line of identity plots did not disclose any systematic error, but revealed substantial variation, indicating a mismatch between TDI and sonomicrometry. CONCLUSIONS It is feasible to quantify postischemic myocardial stunning by TDI in a large size porcine model using longitudinal postsystolic shortening, and postsystolic index as indicators. TDI and sonomicrometry data reach the same end point, but the two techniques are not interchangeable when investigating myocardial stunning close to apex in reference to longitudinal strain and strain rate.
- Subjects :
- Myocardial Stunning
Analysis of Variance
medicine.medical_specialty
Myocardial stunning
Strain (chemistry)
Longitudinal strain
Swine
business.industry
Hemodynamics
Strain rate
medicine.disease
Doppler imaging
Echocardiography, Doppler
Disease Models, Animal
Sonomicrometry
Internal medicine
medicine
Cardiology
Animals
Female
Radiology, Nuclear Medicine and imaging
Cardiology and Cardiovascular Medicine
business
Large size
Subjects
Details
- ISSN :
- 15408175 and 07422822
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- Echocardiography
- Accession number :
- edsair.doi.dedup.....e102d573aef07f0b8e65b1eef630e2aa
- Full Text :
- https://doi.org/10.1111/j.1540-8175.2007.00498.x