Back to Search
Start Over
Hydroxyl-containing porous organic framework coated stir bar sorption extraction combined with high performance liquid chromatography-diode array detector for analysis of triazole fungicides in grape and cabbage samples
- Source :
- Journal of Chromatography A. 1633:461628
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- In this work, a hydroxyl-containing porous organic framework (HC-POF) was prepared by a simple solvothermal reaction with 1,4-phthalaldehyde and phloroglucinol as monomers. Sol-gel method was used to coat HC-POF on the glass stir bar. The prepared HC-POF coated stir bar shows better extraction performance for six triazole fungicides (TFs) compared to commercial polydimethylsiloxane and ethylene glycol-silicone coated stir bars. Fourier transform infrared Spectrometry and X-ray photoelectron Spectrometry were used to explore interactions between HC-POF coating and TFs. It is assumed that the coating mainly adsorbs TFs through π-π interactions, hydrogen bonding and hydrophobic interactions. Based on this fact, a new method of HC-POF coated stir bar sorptive extraction combined with high performance liquid chromatography-diode array detector was developed for the determination of six TFs in grape and cabbage samples. A series of extraction and desorption conditions were carefully optimized, including salt concentration, sample solution pH, stirring rate and desorption solvent. Under the optimized experimental conditions, the proposed method displayed limits of detection in the range of 0.022 -0.071 μg L-1, which is the lowest among the reported SBSE methods for target TFs analysis. The linear range for six TFs was 0.1/0.2-500 μg L-1 and the recoveries for the spiked grape and cabbage were 81.0-109% and 80.7-111%, respectively.
- Subjects :
- Liquid-Liquid Extraction
Brassica
010402 general chemistry
Mass spectrometry
01 natural sciences
Biochemistry
High-performance liquid chromatography
Analytical Chemistry
chemistry.chemical_compound
Limit of Detection
Chromatography detector
Desorption
Vitis
Dimethylpolysiloxanes
Chromatography, High Pressure Liquid
Metal-Organic Frameworks
Detection limit
Chromatography
Polydimethylsiloxane
010401 analytical chemistry
Organic Chemistry
Extraction (chemistry)
Reproducibility of Results
Sorption
General Medicine
Triazoles
Fungicides, Industrial
0104 chemical sciences
chemistry
Adsorption
Porosity
Food Analysis
Subjects
Details
- ISSN :
- 00219673
- Volume :
- 1633
- Database :
- OpenAIRE
- Journal :
- Journal of Chromatography A
- Accession number :
- edsair.doi.dedup.....e095946c377ecf3277ececd40f6af01f
- Full Text :
- https://doi.org/10.1016/j.chroma.2020.461628