Back to Search Start Over

Arthroscopic osteosynthesis of capitellum fractures: Feasibility study and clinical study on 2 cases

Authors :
Christian Sommaire
Philippe Clavert
Valérie Matter-Parrat
David Eichler
Philippe Gicquel
Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie (ICube)
École Nationale du Génie de l'Eau et de l'Environnement de Strasbourg (ENGEES)-Université de Strasbourg (UNISTRA)-Institut National des Sciences Appliquées - Strasbourg (INSA Strasbourg)
Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Institut National de Recherche en Informatique et en Automatique (Inria)-Les Hôpitaux Universitaires de Strasbourg (HUS)-Centre National de la Recherche Scientifique (CNRS)-Matériaux et Nanosciences Grand-Est (MNGE)
Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Réseau nanophotonique et optique
Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Centre National de la Recherche Scientifique (CNRS)
Source :
Journal of Orthopaedic Science, Journal of Orthopaedic Science, 2021, 26 (4), ⟨10.1016/j.jos.2020.05.018⟩
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

Background The current management of displaced capitellum fractures is traditionally surgical. Most authors perform open reduction and internal fixation. The working hypothesis was that closed reduction and internal fixation of capitellum fractures is achievable by arthroscopy. Methods We carried out a cadaveric study on six fresh frozen elbows. We performed two Bryan and Morrey type I fractures of the capitellum, three type II and one type IV using a 15 mm osteotome. Fracture reduction was performed under arthroscopy using a probe hook and an aiming femoral instrument set. Fixation with a lag screw was performed under arthroscopy and radioscopic control. We reviewed, two patients who had been operated on for a type I and type II capitellum fracture and osteosynthesized under arthroscopy with a 7.5 years follow-up. Results In our cadaveric study, we obtained anatomical reduction and stable osteosynthesis in four cases. We had two failures (2 type II fractures) due to a fracture of the fragment during screwing. In our clinical study, range of motion was very satisfactory with only a 5° extension deficit. The x-rays did not reveal any signs of osteoarthritis or periarticular ossification. One patient had minimal signs of osteonecrosis. Conclusions Arthroscopic osteosynthesis of capitellum fractures is feasible and reproducible. We recommend cannulated lag screws for Bryan and Morrey type I and IV fractures and adjustable lock pins for type II fractures. We have shown that this technique gives good results on two patients with a 7.5-year follow-up. Level of evidence IV.

Details

ISSN :
09492658 and 14362023
Volume :
26
Database :
OpenAIRE
Journal :
Journal of Orthopaedic Science
Accession number :
edsair.doi.dedup.....e010a01f7c6514d2e4a1e527cc391594