Back to Search Start Over

The throughput calibration of the VERITAS telescopes

Authors :
Adams, C. B.
Benbow, W.
Brill, A.
Buckley, J. H.
Christiansen, J. L.
Falcone, A.
Feng, Q.
Finley, J. P.
Foote, G. M.
Fortson, L.
Furniss, A.
Giuri, C.
Hanna, D.
Hassan, T.
Hervet, O.
Holder, J.
Hona, B.
Humensky, T. B.
Jin, W.
Kaaret, P.
Kleiner, T. K.
Kumar, S.
Lang, M. J.
Lundy, M.
Maier, G.
Moriarty, P.
Mukherjee, R.
Rosillo, M. Nievas
O'Brien, S.
Park, N.
Patel, S.
Pfrang, K.
Pohl, M.
Prado, R. R.
Pueschel, E.
Quinn, J.
Ragan, K.
Reynolds, P. T.
Ribeiro, D.
Roache, E.
Ryan, J. L.
Santander, M.
Weinstein, A.
Williams, D. A.
Williamson, T. J.
Source :
Astronomy and astrophysics 658, A83 (2022). doi:10.1051/0004-6361/202142275
Publication Year :
2022
Publisher :
EDP Sciences, 2022.

Abstract

Astronomy and astrophysics 658, A83 (2022). doi:10.1051/0004-6361/202142275<br />Context. The response of imaging air Cherenkov telescopes to incident $γ$-ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and $γ$-ray fluxes.Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging air cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy.Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired $γ$-ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.<br />Published by EDP Sciences, Les Ulis

Details

Language :
English
ISSN :
00046361
Database :
OpenAIRE
Journal :
Astronomy and astrophysics 658, A83 (2022). doi:10.1051/0004-6361/202142275
Accession number :
edsair.doi.dedup.....ddad9cf1b1690e8c39c5d2b71d1c98d3
Full Text :
https://doi.org/10.3204/PUBDB-2021-05467