Back to Search Start Over

The influence of stereoscopic vision on surgical performance in minimal invasive surgery-a substudy of the IDOSP-Study (Influence of 3D- vs. 4 K-Display Systems on Surgical Performance in minimal invasive surgery)

Authors :
Caroline Gietzelt
Rabi Datta
Jana Busshoff
Thomas Bruns
Roger Wahba
Andrea Hedergott
Source :
Langenbeck's archives of surgery. 407(7)
Publication Year :
2022

Abstract

Purpose This study is a secondary analysis of the IDOSP trial published in the Annals of Surgery 2020. The aim of this study was to examine the influence of stereo acuity on surgical performance in a laparoscopic training parkour with 3D- versus 4 K-2D-display technique. Methods The surgical performance of medical students (MS), non-board-certified surgeons (NBC), and board-certified surgeons (BC) was compared using 3D- versus 4 K-2D-display technique at a training parkour in a randomized cross-over trial. Stereo acuity was tested by TNO and Titmus Stereo tests. Results Eighty-nine participants were included in this sub-trial. The median stereo acuity for all participants, measured with the Titmus test, was 25 s arc, with TNO test 30 s arc. Higher quality stereo vision, measured with the Titmus test, correlated significantly with a reduced parkour time (r = 0.26, p = 0.02) and error (r = 0.21, p = 0.048) with the 3D screen. The TNO test did not correlate significantly with parkour performance. There was no statistically significant correlation between parkour time nor error and stereo acuity using the 4 K system (p > 0.457 respectively). Higher age showed a significant correlation with lower stereo acuity measured with TNO (r = 0.21, p = 0.014), but not with the Titmus test (r = − 0.7, p = 0.39). Seven percent of the group “NBC and BC” showed reduced stereo acuity > 120 s arc with the Titmus test and 3% with the TNO test. Conclusion High-quality stereo vision is of utmost importance for surgical skills using a 3D-display system. This was most obvious for MS and for tasks that place particularly high demands on hand–eye coordination. The Titmus test was more precise than the TNO test to predict the benefit of a 3D monitor system. Experience and fine motor skills could partly compensate for a poorer stereo acuity. Trial registration This trial was registered at clinicaltrials.gov (trial number: NCT03445429, registered February 26, 2018).

Details

ISSN :
14352451 and 03445429
Volume :
407
Issue :
7
Database :
OpenAIRE
Journal :
Langenbeck's archives of surgery
Accession number :
edsair.doi.dedup.....dd7310eb2981668931d164ef9e832547