Back to Search
Start Over
Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition
- Source :
- European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V. 85(3 Pt)
- Publication Year :
- 2013
-
Abstract
- The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors.
- Subjects :
- Light
Chemistry, Pharmaceutical
Analytical chemistry
Pharmaceutical Science
Excipient
Administration, Oral
Biological Availability
Light scattering
Excipients
Microtiter plate
Fenofibrate
Nephelometry and Turbidimetry
False positive paradox
medicine
Chemical Precipitation
Scattering, Radiation
Technology, Pharmaceutical
False Positive Reactions
Turbidity
Chromatography
Nephelometer
Chemistry
Precipitation (chemistry)
Lasers
Reproducibility of Results
General Medicine
Dipyridamole
Hydrogen-Ion Concentration
Solubility
Area Under Curve
Calibration
Plate reader
Biotechnology
medicine.drug
Subjects
Details
- ISSN :
- 18733441
- Volume :
- 85
- Issue :
- 3 Pt
- Database :
- OpenAIRE
- Journal :
- European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V
- Accession number :
- edsair.doi.dedup.....dd5106cfaba5fe0d845a3c6a65fec12d