Back to Search
Start Over
Pre-production and quality assurance of the Mu2e calorimeter Silicon Photomultipliers
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nuclear Instruments and Methods in Physics Research A 912(2018), 347-349, INSPIRE-HEP
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to $\sim$8.5~$\times$~10$^{11}$ 1 MeV (Si) eq. n/cm$^{2}$ and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than $\sim$10$^{6}$ hours.<br />Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours (France)
- Subjects :
- Nuclear and High Energy Physics
Physics - Instrumentation and Detectors
FOS: Physical sciences
Photodetector
7. Clean energy
01 natural sciences
High Energy Physics - Experiment
High Energy Physics - Experiment (hep-ex)
Radiation damage
Silicon photomultiplier
0103 physical sciences
Mu2e
Breakdown voltage
Neutron
010306 general physics
Silicon Photomultiplier
Instrumentation
Radiation hardening
Physics
Calorimeter
Calorimeter (particle physics)
010308 nuclear & particles physics
business.industry
Instrumentation and Detectors (physics.ins-det)
Quality assurance
Optoelectronics
business
Dark current
Subjects
Details
- ISSN :
- 01689002
- Volume :
- 912
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi.dedup.....dc0280bac0c5136fa3a8438f88283593