Abstract
- Background: The aim of the study was to evaluate the safety and reliability of automatic ventricular pacing threshold measurement, the Medtronic Capture Management™ (CM), in children with epicardial pacing leads. CM has not been recommended for use with epicardial leads due to lack of pertinent data. Methods: During a 2-year study period, 34 children (mean age 6.1 years, range 0 days to 17.7 years) with epicardial leads were prospectively enrolled. The CM measurements were compared with in-office ventricular pacing threshold measurements. Thirty bipolar and five unipolar epicardial leads were assessed. Results: CM measurements were successful and reliable in 30 out of 35 leads (86%). The mean threshold with CM was 1.16 V (95% CI 1.07–1.26 V), and with standard measurement was 1.18 V (95% CI 1.09–1.28 V), at a pulse width of 0.40 ms. The reasons for failure were evoked response undersensing in two cases (5.7%), and high intrinsic rate in one case. High pacing thresholds prevented accurate CM measurements in two cases. Conclusions: CM automatic threshold measurements are consistent with standard ventricular pacing threshold measurements in children with epicardial leads. We recommend a period of monitoring CM performance before programming it to adjust output according to automatic threshold measurements, in order to find the patients in whom it does not work. The CM feature provides increased pacing safety when it measures well (86% of leads). A larger study is needed to prove the tendency for extending battery life in children with epicardial leads.
- Subjects :
- Heart Defects, Congenital
Male
medicine.medical_specialty
Adolescent
Epicardial pacing
Heart Ventricles
Automatic threshold
030204 cardiovascular system & hematology
03 medical and health sciences
Electrocardiography
0302 clinical medicine
Internal medicine
medicine
Humans
030212 general & internal medicine
Prospective Studies
Child
Finland
business.industry
Infant, Newborn
Infant
Mean age
General Medicine
Ventricular pacing
Electrodes, Implanted
Treatment Outcome
Child, Preschool
Cardiology
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 01478389
- Volume :
- 29
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Pacing and clinical electrophysiology : PACE
- Accession number :
- edsair.doi.dedup.....da10ba4737177024eafe7ec1cccceeb6