High-speed rotating device for X-ray tomography with 10 ms temporal resolution

Authors :
Yasumasa Bito
Ryo Mashita
Wataru Yashiro
Hiroyuki Kishimoto
Daisuke Kaneko
Source :
Journal of synchrotron radiation. 28(Pt 1)
Publication Year :
2020

Abstract

The temporal resolution of X-ray tomography, using a synchrotron radiation X-ray source, has been improved to millisecond order in recent years. However, the sample must be rotated at a speed of more than a few thousand revolutions per minute, which makes it difficult to control the environment around the sample. In this study, a high-speed rotation device has been developed, comprising two synchronized coaxial motors movable along the direction of the axis, which can stretch or compress the rotating sample. Using this device, tomograms of breaking rubber were successfully obtained at a temporal resolution of 10 ms.