Back to Search Start Over

Computational modeling of high frequency oscillations recorded with clinical intracranial macroelectrodes

Authors :
M. Khalil
W. El Falou
Mohamad Shamas
Fabrice Wendling
Isabelle Merlet
Pascal Benquet
Faculty of Engineering I (FACULTY OF ENGINEERING I)
Lebanese University [Beirut] (LU)
Laboratoire Traitement du Signal et de l'Image (LTSI)
Université de Rennes 1 (UR1)
Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Centre AZM pour la Recherche en Biotechnologie et ses Applications
Université Libanaise
Université de Rennes (UR)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Source :
38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016, 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016, Aug 2016, Orlando, United States. pp.1014--1017, ⟨10.1109/EMBC.2016.7590874⟩, EMBC
Publication Year :
2016
Publisher :
HAL CCSD, 2016.

Abstract

International audience; High Frequency Oscillations (HFOs) are a potential biomarker of epileptogenic regions. They have been extensively investigated in terms of automatic detection, classification and feature extraction. However, the mechanisms governing the generation of HFOs as well as the observability conditions on clinical intracranial macroelectrodes remain elusive. In this paper, we propose a novel physiologically-relevant macroscopic model for accurate simulation of HFOs as invasively recorded in epileptic patients. This model accounts for both the temporal and spatial properties of the cortical patch at the origin of epileptiform activity. Indeed, neuronal populations are combined with a 3D geometrical representation to simulate an extended epileptic source. Then, by solving the forward problem, the contributions of neuronal population signals are projected onto intracerebral electrode contacts. The obtained signals are qualitatively and quantitatively compared to real HFOs, and a relationship is drawn between macroscopic model parameters such as synchronization and spatial extent on the one hand, and HFO features such as the wave and fast ripple (200-600 Hz) components, on the other hand. © 2016 IEEE.

Details

Language :
English
Database :
OpenAIRE
Journal :
38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016, 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016, Aug 2016, Orlando, United States. pp.1014--1017, ⟨10.1109/EMBC.2016.7590874⟩, EMBC
Accession number :
edsair.doi.dedup.....d9bf811572492b5138e9fd20452532b8
Full Text :
https://doi.org/10.1109/EMBC.2016.7590874⟩