Back to Search Start Over

Fate of filter materials and microbial communities during vermifiltration process

Authors :
Harinaivo A. Andrianisa
Yacouba Konate
Amadou Hama Maiga
Amare Tiruneh Adugna
Source :
Journal of Environmental Management
Publication Year :
2019
Publisher :
Elsevier BV, 2019.

Abstract

The fate of filter materials and microbial communities during the vermifiltration process were studied for 5 months while treating the concentrated greywater. Four filters were filled with 10 cm gravel of which a layer of medium size gravel (5 cm thickness, aggregate size 20–40 mm) at the bottom and a layer of coarse gravel (5 cm thickness, aggregate size 10–20 mm) at the top, then filled with 20 cm sand (d60 = 0.2 mm, d10 = 0.118 mm). Finally, Vermifilter 1 (VF1), control unit and Vermifilter 2 (VF2), were filled with 40 cm fine sawdust (0.05–5 mm) but Vermifilter 3 (VF3), was filled with 40 cm cow dung (0.05–5 mm). Three filters were inoculated with 200 individuals of Eudrilus eugeniae except for the control unit which was filled with sawdust. Five sampling ports were installed on the wall of the filters at 10 cm intervals with reference to the surface of the top layer. Three of the filters were supplied with concentrated greywater and VF1 was supplied with drinking water at the hydraulic loading rate of 16 L m−2.d−1 on batch basis, i.e., four times a day at 8:00 a.m., 11:00 a.m., 2:00 p.m. and 5:00 p.m. Weekly, samples from influent and effluent, and monthly, samples of filter materials collected via sampling ports, were collected and analyzed.The removal efficiencies of biological oxygen demand (BOD5), total chemical oxygen demand (tCOD), and dissolved chemical oxygen demand (dCOD) of VF2 and VF3 were 5–7% higher than the control unit, but little differences were observed in terms of total suspended solids (TSS). However, the removal efficiencies of nutrients for the control unit was slightly better than VF2 and VF3. The pH and Moisture content (MC) of filter materials increased along the depth, but percentage of volatile solids to total solids (VS/TS) decreased through time due to the high number of microbial communities and earthworms dominating the top layer compared to the bottom. The performance of VF2-sawdust was slightly better than VF3-cow dung to treat concentrated greywater.<br />Highlights • Fate of filter materials and microbial communities during vermifiltration process were studied. • Ratio of volatile solids to total solids decreased during vermifiltration process in filter materials. • The bacteria, actinomycetes and fungi intensified where earthworms dominated. • VF2-Sawdust performed slightly better than the VF3-Cow dung.

Details

ISSN :
03014797
Volume :
242
Database :
OpenAIRE
Journal :
Journal of Environmental Management
Accession number :
edsair.doi.dedup.....d93c84f024c6472d52a20008310425c5
Full Text :
https://doi.org/10.1016/j.jenvman.2019.04.076