Back to Search Start Over

Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT)

Authors :
Michael R. Gold
Edgar Lichstein
Jeffrey J. Goldberger
Heinz F. Pitschner
Paul J. Wang
Wojciech Zareba
Mary Beth Brown
Helmut U. Klein
David S. Cannom
Scott McNitt
Mayer Rashtian
Arthur J. Moss
James P. Daubert
Michael Eldar
Sami Viskin
Scott D. Solomon
Ilan Goldenberg
W. Jackson Hall
Iwona Cygankiewicz
Source :
Circulation. 123:1061-1072
Publication Year :
2011
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2011.

Abstract

Background— This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) trial. Methods and Results— Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly ( P P P =0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly ( P Conclusions— Heart failure patients with New York Heart Association class I or II and ejection fraction ≤30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00180271.

Details

ISSN :
15244539 and 00097322
Volume :
123
Database :
OpenAIRE
Journal :
Circulation
Accession number :