Back to Search
Start Over
A comparative study between the imaging system and the optical tracking system in proton therapy at CNAO
- Source :
- Journal of Radiation Research
- Publication Year :
- 2013
-
Abstract
- The synergy between in-room imaging and optical tracking, in co-operation with highly accurate robotic patient handling represents a concept for patient-set-up which has been implemented at CNAO (Centro Nazionale di Adroterapia Oncologica). In-room imaging is based on a double oblique X-ray projection system; optical tracking consists of the detection of the position of spherical markers placed directly on the patient's skin or on the immobilization devices. These markers are used as external fiducials during patient positioning and dose delivery. This study reports the results of a comparative analysis between in-room imaging and optical tracking data for patient positioning within the framework of high-precision particle therapy. Differences between the optical tracking system (OTS) and the imaging system (IS) were on average within the expected localization accuracy. On the first 633 fractions for head and neck (HN) set-up procedures, the corrections applied by the IS, after patient positioning using the OTS only, were for the mostly sub-millimetric regarding the translations (0.4 ± 1.1 mm) and sub-gradual regarding the rotations (0.0° ± 0.8°). On the first 236 fractions for pelvis localizations the amplitude of the corrections applied by the IS after preliminary optical set-up correction were moderately higher and more dispersed (translations: 1.3 ± 2.9 mm, rotations 0.1 ± 0.9°). Although the indication of the OTS cannot replace information provided by in-room imaging devices and 2D-3D image registration, the reported data show that OTS preliminary correction might greatly support image-based patient set-up refinement and also provide a secondary, independent verification system for patient positioning.
- Subjects :
- Health Physics and Radiation Effects
Computer science
Health, Toxicology and Mutagenesis
medicine.medical_treatment
Chondrosarcoma
Image registration
030218 nuclear medicine & medical imaging
head and neck
03 medical and health sciences
0302 clinical medicine
Imaging, Three-Dimensional
Patient Handling
medicine
Chordoma
Image Processing, Computer-Assisted
Proton Therapy
Humans
Radiology, Nuclear Medicine and imaging
Computer vision
Proton therapy
IGRT
Image-guided radiation therapy
Radiation
Particle therapy
Radiotherapy
business.industry
X-Rays
Optical Devices
Reproducibility of Results
Robotics
Dose-Response Relationship, Radiation
Equipment Design
patient positioning
Bioingegneria
optical tracking system
Combined techniques/Organ specific/Related
Optical tracking
particle therapy
Head and Neck Neoplasms
030220 oncology & carcinogenesis
Artificial intelligence
pelvis localizations
Fiducial marker
business
Nuclear medicine
Algorithms
Subjects
Details
- ISSN :
- 13499157
- Volume :
- 54
- Database :
- OpenAIRE
- Journal :
- Journal of radiation research
- Accession number :
- edsair.doi.dedup.....d69b38f9fa8e84d2417db027dad3b50f