Back to Search
Start Over
Controlled sequential elevation of the head and thorax combined with active compression decompression cardiopulmonary resuscitation and an impedance threshold device improves neurological survival in a porcine model of cardiac arrest
- Source :
- Resuscitation
- Publication Year :
- 2020
-
Abstract
- Aim of the study Controlled sequential elevation of the head and thorax (CSE) during active compression decompression (ACD) cardiopulmonary resuscitation (CPR) with an impedance threshold device (ITD) has been shown to increase cerebral perfusion pressure and cerebral blood flow in previous animal studies as compared to the traditional supine position. The potential for this novel bundled treatment strategy to improve survival with intact neurological function is unknown. Methods Female farm pigs were sedated, intubated, and anesthetized. Central arterial and venous access were continuously monitored. Regional brain tissue perfusion (CerO2) was also measured transcutaneous. Ventricular fibrillation (VF) was induced and untreated for 10 min. Pigs were randomized to (1) Conventional CPR (C-CPR) flat or (2) ACD + ITD CSE CPR that included 2 min of ACD + ITD with the head and heart first elevated 10 and 8 cm, and then gradual elevation over 2 min to 22 and 9 cm, respectively. After 19 min of CPR, pigs were defibrillated and recovered. A veterinarian blinded to the intervention assessed cerebral performance category (CPC) at 24 h. A neurologically intact outcome was defined as a CPC score of 1 or 2. Categorical outcomes were analyzed by Fisher's exact test and continuous outcomes with an unpaired student's t-test. Results In 16 animals, return of spontaneous circulation rate was 8/8 (100%) with ACD + ITD CSE and 3/8 (25%) for C-CPR (p = 0.026). For the primary outcome of neurologically intact survival, 6/8 (75%) pigs had a CPC score 1 or 2 with ACD + ITD CSE versus 1/8 (12.5%) with C-CPR (p = 0.04). Coronary perfusion pressure (mmHg, mean ± SD) was higher with CSE at 18 min (41 ± 24 versus 10 ± 5, p = 0.004). rSO2 (%, mean ± SD) and ETCO2 (mmHg, mean ± SD) values were higher at 18 min with CSE (32 ± 9 versus 17 ± 2, p = 0.01, and 55 mmHg ± 10 versus 21 mmHg ± 4, p Conclusions The novel bundled resuscitation approach of CSE with ACD + ITD CPR increased favorable neurological survival versus C-CPR in a swine model of cardiac arrest.
- Subjects :
- Decompression
Resuscitation
Swine
medicine.medical_treatment
030204 cardiovascular system & hematology
Emergency Nursing
Return of spontaneous circulation
Article
03 medical and health sciences
0302 clinical medicine
medicine
Electric Impedance
Animals
Cardiopulmonary resuscitation
Cerebral perfusion pressure
business.industry
030208 emergency & critical care medicine
Impedance threshold device
Thorax
medicine.disease
Cardiopulmonary Resuscitation
Heart Arrest
Cerebral blood flow
Anesthesia
Ventricular fibrillation
Emergency Medicine
Coronary perfusion pressure
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Resuscitation
- Accession number :
- edsair.doi.dedup.....d6266650a212b605e288456fba302665