Back to Search
Start Over
Use of Polyacrylamide as a Tissue-equivalent Material in the Microwave Range
- Source :
- IEEE transactions on biomedical engineering, 35 (1988): 275–277., info:cnr-pdr/source/autori:D.Andreuccetti, M.Bini, A.Ignesti, R.Olmi, N.Rubino, R.Vanni/titolo:Use of Polyacrylamide as a Tissue-equivalent Material in the Microwave Range/doi:/rivista:IEEE transactions on biomedical engineering (Print)/anno:1988/pagina_da:275/pagina_a:277/intervallo_pagine:275–277/volume:35
- Publication Year :
- 1988
- Publisher :
- Institute of Electrical and Electronics Engineers, New York, N.Y. , Stati Uniti d'America, 1988.
-
Abstract
- The use of Polyacrylamide gel to stimulate biological tissues at microwave frequencies is presented; formulation and preparation procedures are discussed. Measurements of complex permittivity in the range from 0.75 to 5.5 GHz, together with its temperature sensitivity are reported. Thermal and otpical properties have also been measured: the polyacrylamide is transparent and may be used as a phantom material in designing and testing applicators for microwave hyperthermia and for dosimetry studies. The use of polyacrylamide gel to simulate biological tissues at microwave frequencies is presenteed. Formulation and preparation procedures are discussed. Measurements of complex permittivity in the range from 0. 75 to 5. 5 GHz, together with its temperature sensitivity, are reported. Thermal and optical properties have also been measured: the polyacrylamide is transparent and may be used as a phantom material in designing and testing applicators for microwave hyperthermia and for dosimetry studies.
- Subjects :
- Permittivity
chemistry.chemical_classification
Materials science
Polyacrylamide
Acrylic Resins
Electric Conductivity
Biomedical Engineering
Polymer
Imaging phantom
Models, Structural
chemistry.chemical_compound
chemistry
Electrical resistivity and conductivity
Dosimetry
Microwave range
Microwaves
Gels
Microwave
Biomedical engineering
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- IEEE transactions on biomedical engineering, 35 (1988): 275–277., info:cnr-pdr/source/autori:D.Andreuccetti, M.Bini, A.Ignesti, R.Olmi, N.Rubino, R.Vanni/titolo:Use of Polyacrylamide as a Tissue-equivalent Material in the Microwave Range/doi:/rivista:IEEE transactions on biomedical engineering (Print)/anno:1988/pagina_da:275/pagina_a:277/intervallo_pagine:275–277/volume:35
- Accession number :