Back to Search Start Over

Prospective imaging comparison of anatomic delineation with rapid kV cone beam CT on a novel ring gantry radiotherapy device

Authors :
Lauren E. Henke
Benjamin W. Fischer-Valuck
Soumon Rudra
Leping Wan
Pamela S. Samson
Amar Srivastava
Prashant Gabani
Michael C. Roach
Imran Zoberi
Eric Laugeman
Sasa Mutic
Clifford G. Robinson
Geoffrey D. Hugo
Bin Cai
Hyun Kim
Source :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 178
Publication Year :
2022

Abstract

A kV imager coupled to a novel, ring-gantry radiotherapy system offers improved on-board kV-cone-beam computed tomography (CBCT) acquisition time (17-40 seconds) and image quality, which may improve CT radiotherapy image-guidance and enable online adaptive radiotherapy. We evaluated whether inter-observer contour variability over various anatomic structures was non-inferior using a novel ring gantry kV-CBCT (RG-CBCT) imager as compared to diagnostic-quality simulation CT (simCT).Seven patients undergoing radiotherapy were imaged with the RG-CBCT system at breath hold (BH) and/or free breathing (FB) for various disease sites on a prospective imaging study. Anatomy was independently contoured by seven radiation oncologists on: 1. SimCT 2. Standard C-arm kV-CBCT (CA-CBCT), and 3. Novel RG-CBCT at FB and BH. Inter-observer contour variability was evaluated by computing simultaneous truth and performance level estimation (STAPLE) consensus contours, then computing average symmetric surface distance (ASSD) and Dice similarity coefficient (DSC) between individual raters and consensus contours for comparison across image types.Across 7 patients, 18 organs-at-risk (OARs) were evaluated on 27 image sets. Both BH and FB RG-CBCT were non-inferior to simCT for inter-observer delineation variability across all OARs and patients by ASSD analysis (p 0.001), whereas CA-CBCT was not (p = 0.923). RG-CBCT (FB and BH) also remained non-inferior for abdomen and breast subsites compared to simCT on ASSD analysis (p 0.025). On DSC comparison, neither RG-CBCT nor CA-CBCT were non-inferior to simCT for all sites (p 0.025).Inter-observer ability to delineate OARs using novel RG-CBCT images was non-inferior to simCT by the ASSD criterion but not DSC criterion.

Details

ISSN :
18790887
Volume :
178
Database :
OpenAIRE
Journal :
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
Accession number :
edsair.doi.dedup.....d403d33f3bfbc919f13dcd941808d765