Quantitative assessment of four-dimensional computed tomography image acquisition quality
- Source :
- Journal of Applied Clinical Medical Physics. 8:1-20
- Publication Year :
- 2007
- Publisher :
- Wiley, 2007.
-
Abstract
- The purpose of the present work was to describe the development and validation of a series of tests to assess the quality of four-dimensional (4D) computed-tomography (CT) imaging as it is applied to radiation treatment planning. Using a commercial respiratory motion phantom and a programmable moving platform with a CT phantom, we acquired 4D CT datasets on two commercial multislice helical CT scanners that use different approaches to 4D CT image reconstruction. Datasets were obtained as the platform moved in various patterns designed to simulate breathing. Known inserts in the phantom were contoured, and statistics were generated to evaluate properties important to radiation therapy--namely, accuracy of phase-binning, shape, volume, and CT number. Phase-binning accuracy varied by as much as 5% for a 4D procedure in which images were reconstructed and then binned, but exhibited no variation for a 4D procedure in which projections were binned before reconstruction. The magnitude of geometric distortion was found to be small for both approaches, as was the magnitude of volume error. Partial-volume effects in the direction perpendicular to the transverse planes of reconstruction affected volume accuracy, however. Computed tomography numbers were reproduced accurately, but 4D images exhibited more variation in CT number than static CT images did. Characterization of such properties can be used to better understand and optimize the various parameters that affect 4D CT image quality.
- Subjects :
- medicine.medical_specialty
Quality Assurance, Health Care
Image quality
Movement
Image registration
Iterative reconstruction
Sensitivity and Specificity
Imaging phantom
Imaging, Three-Dimensional
medicine
Radiology, Nuclear Medicine and imaging
Computer vision
Multislice
Instrumentation
Mathematics
Radiation
Four-Dimensional Computed Tomography
Phantoms, Imaging
business.industry
Reproducibility of Results
Radiographic Image Enhancement
Subtraction Technique
Rotational angiography
Radiographic Image Interpretation, Computer-Assisted
Radiology
Artificial intelligence
Tomography
Artifacts
Tomography, X-Ray Computed
business
Subjects
Details
- ISSN :
- 15269914
- Volume :
- 8
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Clinical Medical Physics
- Accession number :
- edsair.doi.dedup.....d34ed4d50183cf76eceb175f5ea49d9e
- Full Text :
- https://doi.org/10.1120/jacmp.v8i3.2362