Back to Search Start Over

Influence of Alveolar Ridge Morphology and Guide-hole Design on the Accuracy of Static Computer-Assisted Implant Surgery with two Implant Macro-designs: An in Vitro Study

Authors :
Fabrice Alain Dulla
Emilio Couso-Queiruga
Vivianne Chappuis
Burak Yilmaz
Samir Abou-Ayash
Clemens Raabe
Source :
Dulla, Fabrice Alain; Couso-Queiruga, Emilio; Chappuis, Vivianne; Yilmaz, Burak; Abou-Ayash, Samir; Raabe, Clemens (2023). Influence of Alveolar Ridge Morphology and Guide-hole Design on the Accuracy of Static Computer-Assisted Implant Surgery with two Implant Macro-designs: An in Vitro Study. Journal of dentistry, 130(104426), p. 104426. Elsevier Science 10.1016/j.jdent.2023.104426
Publication Year :
2023
Publisher :
Elsevier Science, 2023.

Abstract

OBJECTIVES The primary aim of this in vitro study was to evaluate the influence of alveolar ridge morphologies on the accuracy of static Computer-Assisted Implant Surgery (sCAIS). The secondary aims were to evaluate the influence of guide-hole design and implant macro-design on the accuracy of the final implant position. METHODS Eighteen standardized partially edentulous maxillary models with two different types of alveolar ridge morphologies were used. Each model was scanned via cone beam computer tomography prior to implant placement and scanned with a laboratory scanner prior to and following implant placement using sCAIS. The postsurgical scans were superimposed on the initial treatment planning position to measure the deviations between planned and postsurgical implant positions. RESULTS Seventy-two implants were equally distributed to the study groups. Implants placed in healed alveolar ridges showed significantly lower mean deviations at the crest (0.36 ± 0.17 mm), apex (0.69 ± 0.36 mm), and angular deviation (1.86 ± 0.99°), compared to implants placed in fresh extraction sites (0.80 ± 0.29 mm, 1.61 ± 0.59 mm, and 4.33 ± 1.87°; all p

Details

Language :
English
Database :
OpenAIRE
Journal :
Dulla, Fabrice Alain; Couso-Queiruga, Emilio; Chappuis, Vivianne; Yilmaz, Burak; Abou-Ayash, Samir; Raabe, Clemens (2023). Influence of Alveolar Ridge Morphology and Guide-hole Design on the Accuracy of Static Computer-Assisted Implant Surgery with two Implant Macro-designs: An in Vitro Study. Journal of dentistry, 130(104426), p. 104426. Elsevier Science 10.1016/j.jdent.2023.104426 <http://dx.doi.org/10.1016/j.jdent.2023.104426>
Accession number :
edsair.doi.dedup.....d22ef381ed880beba54f8b9800674e62
Full Text :
https://doi.org/10.1016/j.jdent.2023.104426