- Glutaraldehyde-treated, surgical bioprosthetic heart valves undergo structural degeneration within 10–15 years of implantation. Analogous preliminary results were disclosed for percutaneous heart valves (PHVs) realized with similarly-treated tissues. To improve long-term performance, decellularised scaffolds can be proposed as alternative fabricating biomaterials. The aim of this study was to evaluate whether bovine and porcine decellularised pericardia could be utilised to manufacture bioengineered percutaneous heart valves (bioPHVs) with adequate hydrodynamic performance and leaflet resistance to crimping damage. BioPHVs were fabricated by mounting acellular pericardia onto commercial stents. Independently from the pericardial species used for valve fabrication, bioPHVs satisfied the minimum hydrodynamic performance criteria set by ISO 5840-3 standards and were able to withstand a large spectrum of cardiac output conditions, also during extreme backpressure, without severe regurgitation, especially in the case of the porcine group. No macroscopic or microscopic leaflet damage was detected following bioPHV crimping. Bovine and porcine decellularized pericardia are both suitable alternatives to glutaraldehyde-treated tissues. Between the two types of pericardial species tested, the porcine tissue scaffold might be preferable to fabricate advanced PHV replacements for long-term performance. Condensed abstract Current percutaneous heart valve replacements are formulated with glutaraldehyde-treated animal tissues, prone to structural degeneration. In order to improve long-term performance, bovine and porcine decellularised pericardia were utilised to manufacture bioengineered replacements, which demonstrated adequate hydrodynamic behaviour and resistance to crimping without leaflet architectural alteration.
- Subjects :
- Scaffold
Materials science
Percutaneous
Transcatheter aortic
Swine
BIOPROSTHESES
medicine.medical_treatment
Bioengineering
HYDRODYNAMIC PERFORMANCES
02 engineering and technology
Regurgitation (circulation)
TAVR
010402 general chemistry
01 natural sciences
Comparative evaluation
TAVI
Transcatheter Aortic Valve Replacement
Biomaterials
Valve replacement
Materials Testing
medicine
Animals
ANNULUS
Heart valve
Heart valve degeneration
Bioprosthesis
Novel devices
Decellularization
Heart valve degeneration TAVI/TAVR Biomaterials Novel devices ISO standards
LEAFLET INJURY
021001 nanoscience & nanotechnology
Heart Valves
ISO standards
CALCIFICATION
0104 chemical sciences
medicine.anatomical_structure
Mechanics of Materials
Heart Valve Prosthesis
CELLS
COREVALVE
Cattle
IMPLANTATION
0210 nano-technology
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 09284931
- Database :
- OpenAIRE
- Journal :
- Materials Science & Engineering C-Materials for Biological Applications, 123:111936. Elsevier Science
- Accession number :
- edsair.doi.dedup.....d17126758d5d1288452c4755061ad761