Back to Search Start Over

Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia

Authors :
Julie Maria Bøggild Brøsen
Rikke Mette Agesen
Peter Lommer Kristensen
Amra Ciric Alibegovic
Henrik Ullits Andersen
Henning Beck‐Nielsen
Peter Gustenhoff
Troels Krarup Hansen
Christoffer Hedetoft
Tonny Jensen
Charlotte Røn Stolberg
Claus Bogh Juhl
Susanne Søgaard Lerche
Kirsten Nørgaard
Hans‐Henrik Parving
Lise Tarnow
Birger Thorsteinsson
Ulrik Pedersen‐Bjergaard
Source :
Brøsen, J M B, Agesen, R M, Kristensen, P L, Alibegovic, A C, Andersen, H U, Beck-Nielsen, H, Gustenhoff, P, Hansen, T K, Hedetoft, C, Jensen, T, Stolberg, C R, Juhl, C B, Lerche, S S, Nørgaard, K, Parving, H-H, Tarnow, L, Thorsteinsson, B & Pedersen-Bjergaard, U 2023, ' Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia ', Diabetes, Obesity and Metabolism, vol. 25, no. 6, pp. 1557-1565 . https://doi.org/10.1111/dom.15003, Brøsen, J M B, Agesen, R M, Kristensen, P L, Alibegovic, A C, Andersen, H U, Beck-Nielsen, H, Gustenhoff, P, Hansen, T K, Hedetoft, C, Jensen, T, Stolberg, C R, Juhl, C B, Lerche, S S, Nørgaard, K, Parving, H H, Tarnow, L, Thorsteinsson, B & Pedersen-Bjergaard, U 2023, ' Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia ', Diabetes, Obesity and Metabolism, vol. 25, no. 6, pp. 1557-1565 . https://doi.org/10.1111/dom.15003
Publication Year :
2023

Abstract

AimTo compare nocturnal glucose profiles according to hourly plasma glucose measurements during treatment with insulin degludec and insulin glargine U100 in a cohort of people with type 1 diabetes prone to nocturnal severe hypoglycaemia.Materials and methodsThe HypoDeg trial is a 2-year investigator-initiated, randomized, controlled crossover trial in 149 participants randomized to treatment with insulin degludec and insulin glargine U100 for 12 months each. The 51 participants in this predefined substudy stayed at least one night in hospital during each treatment arm for plasma glucose samples to be taken. Endpoints were glucose profiles, including mean plasma glucose, glycaemic variability and risk of hypoglycaemia.ResultsThere were no differences between treatments regarding mean plasma glucose. We saw a flatter glucose profile during insulin degludec compared with insulin glargine U100 treatment, which had a nadir at 4:00 AM, with a subsequent rise. During treatment with insulin degludec, the participants had lower glycaemic variability, with an estimated treatment difference of −4.3% (95% confidence interval [CI] −8.1 to −0.5; P ConclusionBased on nocturnal plasma glucose measurements, treatment with insulin degludec compared with insulin glargine U100 administered in the evening results in lower glycaemic variability and lower risk of nocturnal hypoglycaemia without differences in mean plasma glucose. Aim: To compare nocturnal glucose profiles according to hourly plasma glucose measurements during treatment with insulin degludec and insulin glargine U100 in a cohort of people with type 1 diabetes prone to nocturnal severe hypoglycaemia. Materials and methods: The HypoDeg trial is a 2-year investigator-initiated, randomized, controlled crossover trial in 149 participants randomized to treatment with insulin degludec and insulin glargine U100 for 12 months each. The 51 participants in this predefined substudy stayed at least one night in hospital during each treatment arm for plasma glucose samples to be taken. Endpoints were glucose profiles, including mean plasma glucose, glycaemic variability and risk of hypoglycaemia. Results: There were no differences between treatments regarding mean plasma glucose. We saw a flatter glucose profile during insulin degludec compared with insulin glargine U100 treatment, which had a nadir at 4:00 AM, with a subsequent rise. During treatment with insulin degludec, the participants had lower glycaemic variability, with an estimated treatment difference of −4.3% (95% confidence interval [CI] −8.1 to −0.5; P < 0.05). Participants treated with insulin degludec were less likely to experience nocturnal hypoglycaemia below 3.0 mmol/L (hazard ratio 0.36 [95% CI 0.17-0.73; P < 0.05]). Conclusion: Based on nocturnal plasma glucose measurements, treatment with insulin degludec compared with insulin glargine U100 administered in the evening results in lower glycaemic variability and lower risk of nocturnal hypoglycaemia without differences in mean plasma glucose.

Details

Language :
English
Database :
OpenAIRE
Journal :
Brøsen, J M B, Agesen, R M, Kristensen, P L, Alibegovic, A C, Andersen, H U, Beck-Nielsen, H, Gustenhoff, P, Hansen, T K, Hedetoft, C, Jensen, T, Stolberg, C R, Juhl, C B, Lerche, S S, Nørgaard, K, Parving, H-H, Tarnow, L, Thorsteinsson, B & Pedersen-Bjergaard, U 2023, ' Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia ', Diabetes, Obesity and Metabolism, vol. 25, no. 6, pp. 1557-1565 . https://doi.org/10.1111/dom.15003, Brøsen, J M B, Agesen, R M, Kristensen, P L, Alibegovic, A C, Andersen, H U, Beck-Nielsen, H, Gustenhoff, P, Hansen, T K, Hedetoft, C, Jensen, T, Stolberg, C R, Juhl, C B, Lerche, S S, Nørgaard, K, Parving, H H, Tarnow, L, Thorsteinsson, B & Pedersen-Bjergaard, U 2023, ' Effect of insulin degludec versus insulin glargine U100 on nocturnal glycaemia assessed by plasma glucose profiles in people with type 1 diabetes prone to nocturnal severe hypoglycaemia ', Diabetes, Obesity and Metabolism, vol. 25, no. 6, pp. 1557-1565 . https://doi.org/10.1111/dom.15003
Accession number :
edsair.doi.dedup.....d07099b522b8b06a592ab8b2f03b35f9