Back to Search
Start Over
Dysplastic Patellofemoral Joints Lead to a Shift in Contact Forces: A 3D-Printed Cadaveric Model
- Source :
- The American journal of sports medicine. 49(12)
- Publication Year :
- 2021
-
Abstract
- Background: The distribution of contact forces across the dysplastic patellofemoral joint has not been adequately quantified because models cannot easily mimic the dysplasia of both the trochlea and the patella. Thus, the mechanical consequences of surgical treatments to correct dysplasia cannot be established. Purpose/Hypothesis: The objective of this study was to quantify the contact mechanics and kinematics of normal, mild, and severely dysplastic patellofemoral joints using synthetic mimics of the articulating surfaces on cadavers. We tested the hypothesis that severely dysplastic joints would result in significantly increased patellofemoral contact forces and abnormal kinematics. Study Design: Controlled laboratory study. Method: Patellofemoral dysplasia was simulated in 9 cadaveric knees by replacing the native patellar and trochlear surfaces with synthetic patellar and trochlear implants. For each knee, 3 synthetic surface geometries (normal, showing no signs of dysplasia; mild, exemplifying Dejour type A; and severe, exemplifying Dejour type B) were randomized for implantation and testing. Patellar kinematics and the sum of forces acting on the medial and lateral patellar facets were computed for each knee and for each condition at 10° increments from 0° to 70° of flexion. Results: A pronounced lateral shift in the weighted center of contact of the lateral facet occurred for severely dysplastic knees from 20° to 70° of flexion. Compared with normal geometries, lateral patellar facet forces exhibited a significant increase only with mild dysplasia from 50° to 70° of flexion and with severe dysplasia at 70° of flexion. No measurable differences in medial patellar facet mechanics or joint kinematics occurred. Conclusion: Our hypothesis was rejected: Severely dysplastic joints did not result in significantly increased patellofemoral contact forces and abnormal kinematics in our cadaveric simulation. Rather, severe dysplasia resulted in a pronounced lateral shift in contact forces across the lateral patellar facet, while changes in kinematics and the magnitude of contact forces were not significant. Clinical Relevance: Including dysplasia of both the patella and trochlea is required to fully capture the mechanics of this complex joint. The pronounced lateralization of contact force in severely dysplastic patellofemoral joints should be considered to avoid cartilage overload with surgical manipulation.
- Subjects :
- musculoskeletal diseases
Orthodontics
3d printed
business.industry
Physical Therapy, Sports Therapy and Rehabilitation
Knee kinematics
Patellofemoral joint
Patella
musculoskeletal system
Contact force
Patellofemoral Joint
Contact mechanics
Patellofemoral arthritis
Printing, Three-Dimensional
Cadaver
Pressure
Medicine
Humans
Orthopedics and Sports Medicine
business
Cadaveric spasm
Subjects
Details
- ISSN :
- 15523365
- Volume :
- 49
- Issue :
- 12
- Database :
- OpenAIRE
- Journal :
- The American journal of sports medicine
- Accession number :
- edsair.doi.dedup.....d0076fcf9e0b9cff585a31b6a2008b1c