Back to Search Start Over

Case study for experimental validation of a new presizing tool for solar heating, cooling and domestic hot water closed systems

Authors :
Hamza Semmari
Jean-Philippe Praene
Amandine LeDenn
Franck Lucas
François Boudéhenn
Olivier Marc
École Nationale Polytechnique de Constantine
Laboratoire d'Innovation pour les Technologies des Energies Nouvelles et les nanomatériaux (LITEN)
Institut National de L'Energie Solaire (INES)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)
Physique et Ingénierie Mathématique pour l'Énergie, l'environnemeNt et le bâtimenT (PIMENT)
Université de La Réunion (UR)
Source :
Case Studies in Thermal Engineering, Vol 10, Iss C, Pp 272-282 (2017), Case Studies in Thermal Engineering, Case Studies in Thermal Engineering, 2017, 10, pp.272-282. ⟨10.1016/j.csite.2017.07.007⟩, Case Studies in Thermal Engineering, Elsevier, 2017, 10, pp.272-282. ⟨10.1016/j.csite.2017.07.007⟩
Publication Year :
2017
Publisher :
Elsevier, 2017.

Abstract

This paper presents a case study experimental validation of PISTACHE which is a new presizing tool intended for designers and planners. It facilitates pre-design and allows the evaluation of annual performance and the integration potential of solar heating, cooling and domestic hot water closed systems. This new tool has been performed in order to standardize the sizing methodology and the comparison of the SHC&DHW closed systems. The comparison framework used in PISTACHE has been performed using seasonal performance indicators that were issued and gathered from experimental data provided by several operating plants. Thus, PISTACHE is an easy graphical user interface and free downloadable tool. In order to check the reliability of the new developed tool, two configuration modes are investigated in this experimental study: a simple cooling mode (RAFSOL plant) and a double cooling and heating mode (SONNENKRAFT installation). The whole validation process is performed using the GenOpt optimization program to determine the optimum set of internal parameters for PISTACHE tool.