Accuracy Assessment of Catheter Guidance Technology in Electrophysiology Procedures
- Source :
- Journal of Cardiovascular Electrophysiology. 25:74-83
- Publication Year :
- 2013
- Publisher :
- Wiley, 2013.
-
Abstract
- With increasing complexity in electrophysiology (EP) procedures, the use of electroanatomic mapping systems (EAMS) as a supplement to fluoroscopy has become common practice. This is the first study that evaluates spatial and point localization accuracy for 2 current EAMS, CARTO3(®) (Biosense Webster, Diamond Bar, CA, USA) and EnSite Velocity(®) (St. Jude Medical Inc., St. Paul, MN, USA), and for a novel overlay guidance (OG) software (Siemens AG, Forchheim, Germany) in a phantom experiment.A C-arm CT scan was performed on an acrylic phantom containing holes and location markers. Spatial accuracy was assessed for each system using distance measurements involving known markers inside the phantom and properly placed catheters. Anatomical maps of the phantom were acquired by each EAMS, whereas the 3D-based OG software superimposed an overlay image of the phantom, segmented from the C-arm CT data set, onto biplane fluoroscopy. Registration processes and landmark measurements quantitatively assessed the spatial accuracy of each technology with respect to the ground truth phantom. Point localization performance was 0.49 ± 0.25 mm in OG, 0.46 ± 0.17 mm in CARTO3(®) and 0.79 ± 0.83 mm in EnSite(®) . The registration offset between virtual visualization and reality was 1.10 ± 0.52 mm in OG, 1.62 ± 0.77 mm in CARTO3(®) and 2.02 ± 1.21 mm in EnSite(®) . The offset to phantom C-arm CT landmark measurements was 0.30 ± 0.26 mm in OG, 0.24 ± 0.21 mm in CARTO3(®) and 1.32 ± 0.98 mm in EnSite(®) .Each of the evaluated EP guidance systems showed a high level of accuracy; the observed offsets between the virtual 3D visualization and the real phantom were below a clinically relevant threshold of 3 mm.
- Subjects :
- Electroanatomic mapping
medicine.medical_specialty
medicine.diagnostic_test
business.industry
medicine.medical_treatment
Body Surface Potential Mapping
Navigation system
Catheter ablation
Catheter
Imaging, Three-Dimensional
Fluoroscopy
Physiology (medical)
Catheter Ablation
Humans
Medicine
Medical physics
Radiology
Electrophysiologic Techniques, Cardiac
Cardiology and Cardiovascular Medicine
business
Image integration
Subjects
Details
- ISSN :
- 10453873
- Volume :
- 25
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiovascular Electrophysiology
- Accession number :
- edsair.doi.dedup.....cef45be1a046f041157969b15b8570c2
- Full Text :
- https://doi.org/10.1111/jce.12264