Back to Search
Start Over
Pressure-Based Biosensor Integrated with a Flexible Pressure Sensor and an Electrochromic Device for Visual Detection
- Source :
- Analytical Chemistry. 93:2916-2925
- Publication Year :
- 2021
- Publisher :
- American Chemical Society (ACS), 2021.
-
Abstract
- This work demonstrated a pressure-based biosensor integrated with a flexible pressure sensor and an electrochromic device for visual detection. Initially, a sandwich-type immunoreaction for target carcinoembryonic antigen (CEA, as a model analyte) was carried out using the capture antibody (cAb) and platinum nanoparticles-labeled detection antibody (PtNPs-dAb) in a reaction cell. The added hydrogen peroxide (H2O2) could be catalyzed by the PtNPs to generate oxygen (O2). In a sealed chamber, the pressure increased with the overflowing O2. Meanwhile, a skin-inspired flexible pressure sensor with excellent sensing performance was fabricated to monitor the pressure change in real time. Thus, the electrical signal of the pressure sensor could reveal the target concentration. Moreover, a voltage-regulated electrochromic device based on polyaniline (PANI) and tungsten oxide (WO3) was integrated into the platform to provide a visualized readout. According to the electrical signal of the pressure sensor, the electrochromic device would change its color from green to blue, which also revealed the target concentration and could be observed by the naked eye. Under optimal conditions, the biosensor presented a high sensitivity for CEA in a detectable range of 0.2-50 ng/mL. The limit of detection (LOD) was 94 pg/mL. The selectivity, reproducibility, and accuracy were also satisfying. Furthermore, this immunoassay gives a path for developing visualized biosensors in point-of-care settings.
- Subjects :
- Analyte
Metal Nanoparticles
Biosensing Techniques
010402 general chemistry
01 natural sciences
Analytical Chemistry
chemistry.chemical_compound
Limit of Detection
Polyaniline
Platinum
Immunoassay
Detection limit
business.industry
Chemistry
010401 analytical chemistry
Reproducibility of Results
Electrochemical Techniques
Hydrogen Peroxide
Pressure sensor
Carcinoembryonic Antigen
0104 chemical sciences
Electrochromism
Optoelectronics
Naked eye
business
Sensitivity (electronics)
Biosensor
Subjects
Details
- ISSN :
- 15206882 and 00032700
- Volume :
- 93
- Database :
- OpenAIRE
- Journal :
- Analytical Chemistry
- Accession number :
- edsair.doi.dedup.....ce8874ad8e1c9a1b9981884ad87d0339
- Full Text :
- https://doi.org/10.1021/acs.analchem.0c04501