Back to Search
Start Over
The calibration system of the Muon g-2 experiment
- Source :
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 936 (2019): 98–101. doi:10.1016/j.nima.2018.10.045, info:cnr-pdr/source/autori:Driutti, A.; Basti, A.; Bedeschi, F.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Di Falco, S.; Di Sciascio, G.; Di Stefano, R.; Donati, S.; Escalante, O.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Gioiosa, A.; Hampai, D.; Iacovacci, M.; Incagli, M.; Karuza, M.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Nath, A.; Paulett, G.; Piacentino, G. M.; Raha, N.; Santi, L.; Smith, M.; Sorbara, M.; Venanzoni, G./titolo:The calibration system of the Muon g-2 experiment/doi:10.1016%2Fj.nima.2018.10.045/rivista:NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT/anno:2019/pagina_da:98/pagina_a:101/intervallo_pagine:98–101/volume:936, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publication Year :
- 2019
-
Abstract
- The Muon g –2 experiment at Fermilab (E989) plans to measure the muon anomalous magnetic moment to a precision of 140 parts per billion (ppb), which corresponds to a total uncertainty of 1 . 6 × 1 0 − 10 . To achieve this level of precision the experiment must detect more than 1 . 8 × 1 0 11 decay positrons by using the 24 calorimeters distributed around the muon storage ring. Each calorimeter consists of 54 Pb F 2 crystals read out by SiPMs. The response of each of the 1296 channels must be calibrated and monitored to keep uncertainties due to gain fluctuations at the sub-per mil level in the time interval corresponding to one beam fill ( 700 μ s ) and at the sub-percent level on longer time scales. These requirements are much more demanding than those needed by most high energy physics experiments. This paper presents a novel laser-based calibration system that distributes light to all calorimeter cells, while allowing one to correct for laser intensity fluctuations and to monitor the distribution chain stability at unprecedented levels of accuracy. Results on the system performance during the first few months of stored muon operation in 2018 are also presented.
- Subjects :
- Nuclear and High Energy Physics
Physics::Instrumentation and Detectors
Electromagnetic calorimeter
Laser system
Muon g-2
Calibration methods
Optics
01 natural sciences
law.invention
Nuclear physics
law
0103 physical sciences
Calibration
Calibration method
Fermilab
010306 general physics
Instrumentation
Nuclear and High Energy Physic
Physics
Muon
Anomalous magnetic dipole moment
010308 nuclear & particles physics
Calibration methods, Electromagnetic calorimeter, Laser system, Muon g-2, Optics
Electromagnetic calorimeter, Laser system, Muon g-2, Calibration methods, Optics
Laser
Calorimeter
Optic
High Energy Physics::Experiment
Beam (structure)
Storage ring
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 936 (2019): 98–101. doi:10.1016/j.nima.2018.10.045, info:cnr-pdr/source/autori:Driutti, A.; Basti, A.; Bedeschi, F.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Di Falco, S.; Di Sciascio, G.; Di Stefano, R.; Donati, S.; Escalante, O.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Gioiosa, A.; Hampai, D.; Iacovacci, M.; Incagli, M.; Karuza, M.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Nath, A.; Paulett, G.; Piacentino, G. M.; Raha, N.; Santi, L.; Smith, M.; Sorbara, M.; Venanzoni, G./titolo:The calibration system of the Muon g-2 experiment/doi:10.1016%2Fj.nima.2018.10.045/rivista:NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT/anno:2019/pagina_da:98/pagina_a:101/intervallo_pagine:98–101/volume:936, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi.dedup.....ce24436540f029dfd9742ec1a8cccb20
- Full Text :
- https://doi.org/10.1016/j.nima.2018.10.045