Characteristics of a bolus created using thermoplastic sheets for postmastectomy radiation therapy
- Source :
- Radiological physics and technology. 14(2)
- Publication Year :
- 2021
-
Abstract
- This study applied a “shell bolus,” an immobilizing thermoplastic shell locally thickened with extra layers over the radiation target, during postmastectomy radiation therapy (PMRT). We performed ion chamber and film measurements for a solid water phantom for thermoplastic sheets and a gel bolus for dosimetric characterization using a 6-MV X-ray flattening-filter-free (FFF) beam. The air gaps between the body surface for the gel and shell bolus were measured using computed tomography (CT) images in patients who underwent PMRT. This included seven and 13 patients treated with the gel and shell boluses, respectively. A comparison of the dose differences between a 10-mm gel bolus and a 9.6-mm-thick thermoplastic sheet at the surface and 5 cm below the surface showed a 4.2% higher surface dose and 0.5% lower dose at 5-cm depth for the thermoplastic sheet compared to those for the gel bolus. The mean (p = 0.029) and maximum (p
- Subjects :
- Thermoplastic
Materials science
medicine.medical_treatment
Shell (structure)
Physical Therapy, Sports Therapy and Rehabilitation
Breast Neoplasms
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Bolus (medicine)
Body surface
medicine
Humans
Radiology, Nuclear Medicine and imaging
Radiometry
Mastectomy
chemistry.chemical_classification
Radiation
Phantoms, Imaging
Radiotherapy Dosage
General Medicine
Postmastectomy radiation
Radiation therapy
chemistry
030220 oncology & carcinogenesis
Ionization chamber
Female
Biomedical engineering
Subjects
Details
- ISSN :
- 18650341
- Volume :
- 14
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Radiological physics and technology
- Accession number :
- edsair.doi.dedup.....cdafc6e38b3660251484d3cfb76f39c3