Back to Search Start Over

Method for identifying ageing in epoxy‐mica composite insulation used in rotational machines through modelling of dielectric relaxation

Authors :
Biswendu Chatterjee
Sivaji Chakravorti
Nasirul Haque
Nikhil Mondal
Sovan Dalai
Source :
High Voltage (2019)
Publication Year :
2020
Publisher :
Institution of Engineering and Technology (IET), 2020.

Abstract

Dielectric response analysis, performed in time domain and frequency domain is one of the interesting methods used for condition assessment of high voltage equipment. In this article, the degradation of epoxy-mica composite insulation which is widely used in rotating machines has been investigated through frequency domain spectroscopy measurements. Artificial ageing of the carefully prepared stator bar insulation sample was performed through simultaneous application of high temperature and electric field in a designated environmental chamber for specific durations. To study the effect of temperature, the measurements were performed at temperatures ranging from 20 to 60°C at different ageing status. Following experimental work, the measurement results were modelled using Havriliak–Negami model and ageing sensitive parameters were extracted. To study the effect of temperature, the measurements were performed at temperatures ranging from 20 to 60°C. The modelled results matched well with the experimental measurements and certain model parameters sensitive to the ageing condition were identified. The numerical relationships between the insulation status of the stator bar and the aforementioned parameters were identified. It was observed that the nature of the numerical relationship remains identical in the investigated temperature range, although the coefficients vary to some extent.

Details

ISSN :
23977264
Volume :
5
Database :
OpenAIRE
Journal :
High Voltage
Accession number :
edsair.doi.dedup.....ccf5d270e999319f3df61a8a63b298d5