Back to Search
Start Over
Method for identifying ageing in epoxy‐mica composite insulation used in rotational machines through modelling of dielectric relaxation
- Source :
- High Voltage (2019)
- Publication Year :
- 2020
- Publisher :
- Institution of Engineering and Technology (IET), 2020.
-
Abstract
- Dielectric response analysis, performed in time domain and frequency domain is one of the interesting methods used for condition assessment of high voltage equipment. In this article, the degradation of epoxy-mica composite insulation which is widely used in rotating machines has been investigated through frequency domain spectroscopy measurements. Artificial ageing of the carefully prepared stator bar insulation sample was performed through simultaneous application of high temperature and electric field in a designated environmental chamber for specific durations. To study the effect of temperature, the measurements were performed at temperatures ranging from 20 to 60°C at different ageing status. Following experimental work, the measurement results were modelled using Havriliak–Negami model and ageing sensitive parameters were extracted. To study the effect of temperature, the measurements were performed at temperatures ranging from 20 to 60°C. The modelled results matched well with the experimental measurements and certain model parameters sensitive to the ageing condition were identified. The numerical relationships between the insulation status of the stator bar and the aforementioned parameters were identified. It was observed that the nature of the numerical relationship remains identical in the investigated temperature range, although the coefficients vary to some extent.
- Subjects :
- epoxy-mica composite insulation
Materials science
composite insulating materials
Bar (music)
Stator
havriliak–negami model
mica
lcsh:QC501-721
Energy Engineering and Power Technology
Dielectric
dielectric relaxation
stators
law.invention
condition assessment
law
rotational machines
lcsh:Electricity
Time domain
Electrical and Electronic Engineering
Composite material
artificial ageing
environmental chamber
machine insulation
time domain
High voltage
Epoxy
Atmospheric temperature range
time-domain analysis
epoxy insulation
frequency-domain analysis
rotating machines
ageing
Frequency domain
visual_art
visual_art.visual_art_medium
frequency domain spectroscopy measurements
lcsh:Electrical engineering. Electronics. Nuclear engineering
lcsh:TK1-9971
dielectric response analysis
stator bar insulation
Subjects
Details
- ISSN :
- 23977264
- Volume :
- 5
- Database :
- OpenAIRE
- Journal :
- High Voltage
- Accession number :
- edsair.doi.dedup.....ccf5d270e999319f3df61a8a63b298d5