Back to Search
Start Over
Estimation of absorbed radiation doses to skin and S-values for organs at risk due to nasal administration of PET agents using Monte Carlo simulations
- Source :
- Physica Medica. 84:301-302
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Purpose The intranasal (IN) administration of radiopharmaceuticals is of interest in being a viable route for the delivery of radiopharmaceuticals that do not ordinarily cross the blood-brain barrier (BBB). However, to be viable in a patient population, good image quality as well as safety of the administration should be demonstrated. This work provides radiation dosimetry calculations and simulations related to the radiation safety of performing such experiments in a human cohort. Methods We performed Monte Carlo (MC) simulations to estimate radiation dose to the skin inside a cylindrical model of the nasal cavity assuming a homogenous distribution layer of 11 C and 18 F and calculated a geometry conversion factor (FP-C ) which can be used to convert from a planar geometry to a cylindrical geometry using more widely available software tools. We compared radiation doses from our simulated cylindrical geometry with the planar dose estimates employing our geometry conversion factor from VARSKIN 6.1 software and also from an analytical equation. Furthermore, in order to estimate radiation dosimetry to surrounding organs of interest, we performed a voxelized MC simulation of a fixed radioactivity inside the nasal cavity and calculated S-values to organs such as the eyes, thyroid, and brain. Results MC simulations of contamination scenarios using planar absorbed doses of 15.50 and 8.60 mGy/MBq for 18 F and 11 C, respectively, and 35.70 and 19.80 mGy/MBq per hour for cylindrical geometries, leading to determination of an FP-C of 2.3. Planar absorbed doses (also in units of mGy/MBq) determined by the analytical equation were 16.96 and 8.68 (18 F and 11 C) and using VARSKIN were 16.60 and 9.26 (18 F and 11 C), respectively. Application of FP-C to these results demonstrates values with a maximum difference of 9.41% from the cylindrical geometry MC calculation, demonstrating that when accounting for geometry, more simplistic techniques can be utilized to estimate IN dosimetry. Voxelized MC simulations of radiation dosimetry from a fixed source of 1 MBq of activity confined to the nasal cavity resulted in S-values to the thyroid, eyes, and brain of 1.72 x 10-6 , 1.93 x 10-5 , and 3.51 x 10-6 mGy/MBq·s, respectively, for 18 F and 1.80 × 10-6 , 1.95 × 10-5 , and 3.54 × 10-6 mGy/MBq·s for 11 C. Conclusion Dosimetry concerns about IN administrations of PET radiotracers should be considered before clinical use. Values presented in the simulations such as the S-values can be further used for assessment of absorbed doses in cases of IN administration, and can be used to develop and adapt specific study protocols. All three presented methods provided similar results when considering the use of a geometry conversion factor for planar to cylindrical geometry, demonstrating that standard tools rather than dedicate MC simulations may be used to perform dose calculations in nasal administrations.
- Subjects :
- Organs at Risk
Cylindrical geometry
Materials science
Dose calculation
Monte Carlo method
Biophysics
General Physics and Astronomy
Radiation
Radiation Dosage
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Maximum difference
Humans
Dosimetry
Radiology, Nuclear Medicine and imaging
Radiometry
Administration, Intranasal
PET-CT
Phantoms, Imaging
business.industry
General Medicine
Positron-Emission Tomography
030220 oncology & carcinogenesis
Nasal administration
Nuclear medicine
business
Monte Carlo Method
Biomedical engineering
Subjects
Details
- ISSN :
- 11201797
- Volume :
- 84
- Database :
- OpenAIRE
- Journal :
- Physica Medica
- Accession number :
- edsair.doi.dedup.....cbfe760e5f0ffaea3d7cb974c0b2a3d2
- Full Text :
- https://doi.org/10.1016/j.ejmp.2021.01.052