Bronchoscopic removal of an inhaled, sharp, foreign body: an unusual complication
- Source :
- The Journal of laryngology and otology. 113(9)
- Publication Year :
- 2000
-
Abstract
- A case is reported in which an inhaled sewing needle, stuck fast in the trachea, became displaced through the tracheal wall during attempted removal via flexible bronchoscopy. The inherent risks and pitfalls of this procedure are highlighted.
- Subjects :
- Male
medicine.medical_specialty
medicine.diagnostic_test
Adolescent
business.industry
Tracheal wall
General Medicine
Sewing needle
medicine.disease
Foreign Bodies
Endoscopy
Surgery
Radiography
Trachea
Otorhinolaryngology
Bronchoscopy
Needles
medicine
Humans
Surgery operative
Foreign body
Complication