Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

Authors :
Johan Nyberg
X.L. Luo
P. A. Söderström
G. de Angelis
J. Agramunt
Q. Nishada
F.J. Egea
A. Gadea
T. Hüyük
A. Di Nitto
J. J. Valiente-Dobón
V. Modamio
R. Wadsworth
Enrique Sanchis
M. Moszynski
S. Erturk
M. Palacz
G. Jaworski
M. N. Erduran
A. Triossi
Vicente González
Huyuk, Tayfun -- 0000-0003-0597-9767
Millan, Vicente Gonzalez -- 0000-0001-6014-2586
Jaworski, Grzegorz -- 0000-0003-2241-0329
Triossi, Andrea -- 0000-0001-5140-9154
Di Nitto, Antonio -- 0000-0002-9319-366X
SANCHIS, ENRIQUE -- 0000-0002-9689-9131
Gadea, Andres -- 0000-0002-4233-1970
Soderstrom, Par-Anders -- 0000-0002-9504-2814
de France, Gilles -- 0000-0002-7439-1759
[Luo, X. L.] Natl Univ Def Technol, Coll Mechatron & Automat, Dept Instrument Sci & Technol, Changsha, Hunan, Peoples R China -- [Luo, X. L. -- Nyberg, J. -- Nishada, Q.] Uppsala Univ, Dept Phys & Astron, SE-75120 Uppsala, Sweden -- [Modamio, V. -- Valiente-Dobon, J. J. -- de Angelis, G. -- Triossi, A.] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy -- [Agramunt, J. -- Egea, F. J. -- Gadea, A. -- Hueyuek, T.] Univ Valencia, CSIC, IFIC, Valencia, Spain -- [Egea, F. J. -- Gonzalez, V. -- Sanchis, E.] Univ Valencia, Dept Elect Engn, E-46071 Valencia, Spain -- [Erduran, M. N.] Istanbul Sabahattin Zaim Univ, Fac Engn & Nat Sci, Istanbul, Turkey -- [Erturk, S.] Nigde Univ, Fen Edebiyat Falk, Nigde, Turkey -- [de France, G.] CEA DSAM, GANIL, F-14076 Caen 05, France -- [de France, G.] CNRS, IN2P3, F-14076 Caen 05, France -- [Jaworski, G.] Warsaw Univ Technol, Fac Phys, PL-00662 Warsaw, Poland -- [Jaworski, G. -- Moszynski, M. -- Palacz, M.] Warsaw Univ, Heavy Ion Lab, PL-02093 Warsaw, Poland -- [Moszynski, M.] Natl Ctr Nucl Res, PL-05400 Otwock, Poland -- [Di Nitto, A.] Johannes Gutenberg Univ Mainz, D-55099 Mainz, Germany -- [Soederstroem, P. -A.] RIKEN, Nishina Ctr, Wako, Saitama 3510198, Japan -- [Wadsworth, R.] Univ York, Dept Phys, York YO10 5DD, N Yorkshire, England
Grand Accélérateur National d'Ions Lourds (GANIL)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
0-Belirlenecek
Luo, X. L.
Modamio, V.
Nyberg, J.
Valiente-Dobon, J. J.
Nishada, Q.
De Angelis, G.
Agramunt, J.
Egea, F. J.
Erduran, M. N.
Erturk, S.
De France, G.
Gadea, A.
Gonzalez, V.
Huyuk, T.
Jaworski, G.
Moszynski, M.
Di Nitto, A.
Palacz, M.
Soderstrom, P. -A.
Sanchis, E.
Triossi, A.
Wadsworth, R.
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014, In press, ⟨10.1016/j.nima.2014.08.023⟩
Publication Year :
2014
Publisher :
ELSEVIER SCIENCE BV, 2014.

Abstract

WOS: 000344994600012<br />A comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA. (C) 2014 Elsevier B.V. All rights reserved.<br />Swedish Research Council; UK STFC; Generalitat Valenciana, Spain [PROMETEO/2010/101]; MINECO, Spain [AIC-D-2011-0746, FPA2011-29854, FPA2012-33650]; Chinese Scholarship Council (CSC); Science and Technology Facilities Council [ST/J000124/1, ST/L005735/1]<br />This work was partly funded by the Swedish Research Council, by the UK STFC, and by the Generalitat Valenciana, Spain, under Grant PROMETEO/2010/101, and by MINECO, Spain, under Grants AIC-D-2011-0746, FPA2011-29854 and FPA2012-33650. X. L. Luo acknowledges the support of the Chinese Scholarship Council (CSC).

Details

Language :
English
ISSN :
01689002 and 18729576
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014, In press, ⟨10.1016/j.nima.2014.08.023⟩
Accession number :
edsair.doi.dedup.....ca12b7da2c4eef516597eb14998d41ff
Full Text :
https://doi.org/10.1016/j.nima.2014.08.023⟩