Back to Search
Start Over
Outcomes following cryoballoon ablation for atrial fibrillation guided by pressure waveform monitoring without the routine use of pulmonary venography
- Source :
- Journal of Interventional Cardiac Electrophysiology. 49:75-82
- Publication Year :
- 2017
- Publisher :
- Springer Science and Business Media LLC, 2017.
-
Abstract
- Pressure waveform analysis has the potential for facilitated assessment of pulmonary vein occlusion during cryoballoon ablation for atrial fibrillation. Data on clinical outcomes using this method are lacking. We sought to validate through clinical outcomes the use of pressure waveform analysis as the primary method of determining pulmonary vein occlusion during cryoballoon ablation. A study was performed of 122 consecutive patients with atrial fibrillation (85% paroxysmal) undergoing cryoballoon ablation from May 2014 through July 2015 at a single institution using pressure waveform analysis as the primary method of assessing pulmonary vein occlusion. Cryoballoon ablation, with additional segmental radiofrequency ablation in 13.7%, resulted in complete pulmonary vein isolation in 100% of patients. The single procedure freedom from recurrence of atrial arrhythmia beyond the initial 3-month post-ablation was 81.2% at a mean follow-up of 237 days. Recurrence of atrial arrhythmia within 3-month post-ablation was 11.1%, and predicted recurrence beyond 3 months. Repeat ablation was performed in 12.0% of patients. In the largest study to date on this topic and the only study to focus on clinical outcomes, pressure waveform analysis as the primary method of determining pulmonary vein occlusion in cryoballoon ablation of atrial fibrillation resulted in acute and long-term procedural success rates comparable to those reported with use of routine pulmonary venography. Controlled study is needed to confirm these findings and to determine if this technique affects variables such as procedure duration and radiation exposure.
- Subjects :
- Male
medicine.medical_specialty
Radiofrequency ablation
medicine.medical_treatment
Venography
Pressure waveform analysis
030204 cardiovascular system & hematology
Cryosurgery
Sensitivity and Specificity
Pulmonary vein
law.invention
03 medical and health sciences
0302 clinical medicine
Heart Conduction System
law
Monitoring, Intraoperative
Physiology (medical)
Internal medicine
Atrial Fibrillation
Occlusion
medicine
Humans
030212 general & internal medicine
Cryoballoon ablation
medicine.diagnostic_test
business.industry
Reproducibility of Results
Blood Pressure Determination
Atrial fibrillation
Phlebography
Middle Aged
Ablation
medicine.disease
Treatment Outcome
Surgery, Computer-Assisted
Pulmonary Veins
Catheter Ablation
cardiovascular system
Cardiology
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 15728595 and 1383875X
- Volume :
- 49
- Database :
- OpenAIRE
- Journal :
- Journal of Interventional Cardiac Electrophysiology
- Accession number :
- edsair.doi.dedup.....c9f1fe113721b1e4cf80b747fb1eb0b2