Back to Search Start Over

Validity And Reliability Of The Stages Cycling Power Meter

Authors :
Sylvain Dorel
Cyril Granier
Christophe Hausswirth
Le Meur Yann
Institut national du sport et de l'éducation physique (INSEP)
Motricité, interaction, performance EA 4334 (MIP)
Le Mans Université (UM)-Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Université de Nantes (UN)-Université de Nantes (UN)
Motricité, interactions, performance EA 4334 / Movement - Interactions - Performance (MIP)
Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Université de Nantes (UN)-Université de Nantes (UN)-Centre hospitalier universitaire de Nantes (CHU Nantes)-Le Mans Université (UM)
Le Mans Université (UM)-Centre hospitalier universitaire de Nantes (CHU Nantes)-Université de Nantes - UFR des Sciences et Techniques des Activités Physiques et Sportives (UFR STAPS)
Source :
Journal of Strength and Conditioning Research, Journal of Strength and Conditioning Research, Lippincott, Williams & Wilkins, 2018, ⟨10.1519/JSC.0000000000002189⟩
Publication Year :
2018
Publisher :
HAL CCSD, 2018.

Abstract

Granier, C, Hausswirth, C, Dorel, S, and Le Meur, Y. Validity and reliability of the stages cycling power meter. J Strength Cond Res 34(12): 3554-3559, 2020-This study aimed to determine the validity and the reliability of the Stages power meter crank system (Boulder, United States) during several laboratory cycling tasks. Eleven trained subjects completed laboratory cycling trials on an indoor cycle fitted with SRM Professional and Stages systems. The trials consisted of an incremental test at 100 W, 200 W, 300 W, 400 W, and four 7-s sprints. The level of pedaling asymmetry was determined for each cycling intensity during a similar protocol completed on a Lode Excalibur Sport ergometer. The reliability of Stages and SRM power meters was compared by repeating the incremental test during a test-retest protocol on a Cyclus 2 ergometer. Over power ranges of 100-1,250 W, the Stages system produced trivial to small differences compared with the SRM (standardized typical error values of 0.06, 0.24, and 0.08 for the incremental, sprint, and combined trials, respectively). A large correlation was reported between the difference in power output (PO) between the 2 systems and the level of pedaling asymmetry (r = 0.58, p < 0.001). Recalculating PO of the Stages system according to the level of pedaling asymmetry provided only marginal improvements in PO measures. The reliability of the Stages power meter at the submaximal intensities was similar to the SRM Professional model (coefficient of variation: 2.1 and 1.3% for Stages and SRM, respectively). The Stages system is a suitable device for PO measurements, except when a typical error of measurement

Details

Language :
English
ISSN :
10648011 and 15334287
Database :
OpenAIRE
Journal :
Journal of Strength and Conditioning Research, Journal of Strength and Conditioning Research, Lippincott, Williams & Wilkins, 2018, ⟨10.1519/JSC.0000000000002189⟩
Accession number :
edsair.doi.dedup.....c6b65d65321826dd5f1391eb8709da41