Multicenter evaluation of the new immunoassay method for TSH measurement using the automated DxI platform
- Publication Year :
- 2017
- Publisher :
- Elsevier B.V., 2017.
-
Abstract
- Aim of the study Recently, Beckman Coulter Diagnostics set up a new TSH immunoassay for the automated DxI platform. The aim of this study was to evaluate and compare the analytical performance and clinical results of this method with those of previous method. Material and methods A multicenter study (named TSH ELAS Study) was organized using 593 serum samples, collected from healthy subjects and patients with thyroid disorders, and 13 control samples, circulated in an External Quality Assessment (EQA) scheme. Results The values of LoB and LoD, and LoQ at 20% CV were 0.0004 mIU/L, 0.001 mIU/L and 0.0023 mIU/L, respectively. Moreover, TSH concentrations > 0.01 mIU/L actually show imprecision values lower than 5% CV. This new TSH assay showed a systematic underestimation (on average of 6.25%) compared to old method, which is mainly due to larger differences between methods for samples with low TSH concentrations, related to the better analytical sensitivity of new compared to old method. In a reference population, including 279 apparently healthy adult subjects, Caucasian volunteers (mean age 43.6 years, age 20–63 years, 138 women and 141 males) the distribution of TSH concentrations was: mean (CI 95%) 1.694 mIU/L (1.588–1.779), median 1.495 mIU/L (1.412–1.588 mIU/L), 97.5th percentile 3.707 mIU/L. Conclusions The new TSH immunoassay for DxI platform shows some relevant improvements compared to the previous one: use of the most recent WHO 3rd IRP 81/563 standard and monoclonal antibodies (instead of polyclonal antibodies of the old method), and better analytical sensitivities and reproducibility.
- Subjects :
- Male
Percentile
endocrine system diseases
analytical parameters
thyroid tumor
limit of quantitation
Clinical Biochemistry
Thyrotropin
Biochemistry
Automation
0302 clinical medicine
Settore BIO/12 - BIOCHIMICA CLINICA E BIOLOGIA MOLECOLARE CLINICA
sensitivity analysis
Reference Values
DxI platform
middle aged
Medicine
Immunoassay
clinical article
Beckman coulter
limit of detection
medicine.diagnostic_test
Quality specification
immunoassay analyzer
TSH
clinical trial
General Medicine
limit of blank
aged
Immunoassay method
female
030220 oncology & carcinogenesis
standards
hormones, hormone substitutes, and hormone antagonists
Adult
Quality Control
endocrine system
medicine.medical_specialty
Urology
030209 endocrinology & metabolism
Article
young adult, Adult
03 medical and health sciences
Young Adult
evaluation study
blood
Internal medicine
External quality assessment
Humans
controlled study
thyroid disease
human
procedures
Thyroid Neoplasms
intermethod comparison
reproducibility
Reproducibility
business.industry
Biochemistry (medical)
reference value
Reproducibility of Results
case control study
Serum samples
TSH measurement
major clinical study
Immunoassay methods
Endocrinology
thyrotropin blood level
multicenter study
Multicenter study
monoclonal antibody
Case-Control Studies
business
thyrotropin, adult
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :