Back to Search Start Over

Thrombogenicity of a New Injectable Biocompatible Elastomer for Aneurysm Exclusion, Compared to Expanded Polytetrafluoroethylene in a Human Ex Vivo Model

Authors :
Jan M.M. Heyligers
F.L. Moll
T.J. van der Steenhoven
Michael J. Jacobs
P. G. De Groot
Claudia Tersteeg
Willem-Maarten Bosman
Surgery
RS: CARIM School for Cardiovascular Diseases
Source :
European Journal of Vascular and Endovascular Surgery, 43(6), 675-680. Elsevier Saunders
Publisher :
European Society for Vascular Surgery. Published by Elsevier Ltd.

Abstract

Objectives Customized Aortic Repair (CAR) is a new concept for endovascular aortic aneurysm repair in which a non-polymerised elastomer is injected to fill the aneurysm sac around a balloon catheter. Amongst other variables, the thrombogenicity of the elastomer should be tested, before further clinical experiments can take place. The aim of this human ex vivo study was to measure the thrombogenicity of the elastomer and to compare it to expanded polytetrafluoroethylene (ePTFE). Design and materials In a validated ex vivo model, non-anticoagulated blood was drawn from the antecubital veins of 10 healthy donors with a 19-gauge needle. It was drawn through elastomer tubes and through ePTFE Gore-Tex vascular grafts, both 60 cm long and with an inner diameter of 3 mm. Methods Fibrinopeptide A (FPA) and P-selectin expression was measured in blood samples, collected at the end of the grafts. After the experiments, the deposition of platelets and fibrin onto the grafts was visualised by scanning electron microscopy. Results For these graft types, a progressive increase in FPA production was observed in time. No significant difference was observed between the elastomer and ePTFE grafts ( p > 0.05). No increase in P-selectin expression, and thereby no platelet activation, was observed in the perfusate of either grafts ( p > 0.05). By scanning electron microscopy, numerous platelet aggregates were observed on the ePTFE grafts, whereas just a few adhered platelets and no aggregates were observed in the elastomer grafts. Conclusions The elastomer in its current formulation has a low thrombogenicity, comparable to ePTFE, making it an ideal substance for endovascular aneurysm sac filling. Further research should clarify the feasibility of CAR in vivo .

Details

Language :
English
ISSN :
10785884
Issue :
6
Database :
OpenAIRE
Journal :
European Journal of Vascular and Endovascular Surgery
Accession number :
edsair.doi.dedup.....c4027ca72c4d91a840382acc6be78b82
Full Text :
https://doi.org/10.1016/j.ejvs.2012.02.025