Back to Search
Start Over
ATLAS monitored drift tube chambers for super-LHC
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 623:91-93
- Publication Year :
- 2010
- Publisher :
- Elsevier BV, 2010.
-
Abstract
- After the high-luminosity upgrade of the Large Hadron Collider (LHC) at CERN, the ATLAS muon spectrometer is expected to work at 10 times increased background rates of gammas and neutrons. This is challenging as the momentum resolution of the spectrometer is expected to be 10 %. This requires a single tube resolution of the muon drift tubes of 80 mum. At background rates around 1000 Hz/cm2 space charge effects will lead in the slow and non-linear AR:CO2 = 93:7 gas mixture to a degradation of the drift-tube spatial resolution. This was studied before experimentally for gammas and low energetic neutrons. Almost no information exists for fast neutrons. Therefore, we organized our studies under the following aspects: - We investigated the influence of 11 MeV neutrons on the position resolution of ATLAS MDT chambers. At flux densities between 4 and 16 kHz/cm2, almost no influence on the position resolution was found, it degrades by only 10 mum at a detection efficiency of only 4*10-4. - We investigated inert gas mixtures on fastness and linearity of their position-drifttime (r-t) relation. At a reduction of the maximum drift time by a factor of 2, the use of the present hardware and electronics might be possible. For our experimental studies we used our Munich cosmic ray facility. Two gas mixtures show almost identical position resolution as the standard gas. - For spectrometer regions of highest background rates we contributed to the investigation of newly developed 15 mm drift tubes. Position resolutions have been measured as a function of gamma background rates between 0 and 1400 Hz/cm2. - Garfield simulations have been performed to simulate space charge effects due to gamma irradiation. Results will be presented for the standard geometry as well as for the new 15 mm drift tubes.<br />Comment: 3 pages, 7 figures, conference
- Subjects :
- Physics
Nuclear and High Energy Physics
Physics - Instrumentation and Detectors
Muon
Large Hadron Collider
Spectrometer
Physics::Instrumentation and Detectors
Resolution (electron density)
FOS: Physical sciences
Instrumentation and Detectors (physics.ins-det)
Space charge
Neutron temperature
High Energy Physics - Experiment
Nuclear physics
High Energy Physics - Experiment (hep-ex)
Neutron
physics.ins-det
Instrumentation
Image resolution
Subjects
Details
- ISSN :
- 01689002
- Volume :
- 623
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi.dedup.....c3c3fdbf6be1bc593d6a1034861c8c51